Maintenance - Craftsman 919.165361 Owner's Manual

Permanently lubricated portable air compressor

Advertisement

Available languages

Available languages

ALL MAINTENANCE
AND REPAIR
OPERATIONS NOT LISTED MUST
BE PERFORMED
BY A TRAINED
SERVICE TECHNICIAN.
_Risk
of Unsafe
Operation. Unit
cycles automatically
when power is
on. When servicing, you may be
exposed to voltage sources,
compressed
air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to the
air compressor, bleed tank of
pressure, and allow the air
compressor to cool.
To Replace
or Clean Check
Valve
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Set the On/Auto/Off
lever to
"OFF" and unplug unit.
3.
Remove the hose by removing
the hose clamp.
NOTE: The hose clamp is not
reusable. You must purchase a new
hose clamp, see the Parts List
Manual or purchase a standard hose
clamp at a local hardware store.
5.
Unscrew the check valve (turn
counterclockwise)
using a socket
wrench.
6.
Make sure the valve disc moves
freely inside the check valve and
the spring holds the disc in the
upper, closed position. The
check valve may be cleaned with
a solvent, such as paint and
varnish remover.
7.
Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
8.
Replace hose and new hose
clamp.
9.
Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
Hose Clamp
Check
Valve
D30052
16_ ENG