TABLE 1-6
specifications, refer to the SPARC Enterprise M4000/M5000 Servers Site Planning Guide.
Midrange Servers Electrical Specifications
TABLE 1-6
M4000 Server
Number of power
2 (1 power cord per power supply unit)
cords
Redundancy
1 + 1 redundant
Second power supply is redundant at 200 VAC
100–127 VAC
Input voltage
200–240 VAC
24.0A at 100–127 VAC (12A/cord)
Maximum current
12.0A at 200–240 VAC (12A/cord)
50–60 Hz
Frequency
0.98
Power factor
CPU Types and Server Maximum Power Consumption
This section describes the CPU types and the maximum power consumption of the
server.
There are four types of CPU. The power specifications of the M4000/M5000 servers
vary depending on the CPU type and the system configuration.
TABLE 1-7
apparent power, and heat dissipation by the type of CPU. The figures represent the
system configuration described below the table, in which every CPU Modules
(CPUM) is mounted with the same CPU.
Note – Values in
lists the power supply features and some specifications. For additional
and
list the specifications of maximum power consumption,
TABLE 1-8
and
TABLE 1-7
M5000 Server
4 (1 power cord per power supply unit)
2 + 2 redundant
Second and fourth power supplies are
redundant at 200 VAC
100–127 VAC
200–240 VAC
48A at 100–127 VAC (12A/cord)
24A at 200–240 VAC (12A/cord)
50–60 Hz
0.98
are rounded to the nearest whole number.
TABLE 1-8
Chapter 1
System Overview
1-19