Pressure Testing - FCI Home Appliances COGB33060/BL Installation Manual

For cooktops built-in gas
Table of Contents

Advertisement

Available languages

Available languages

Pressure Testing

The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 PSIG (3.5 kPa).
This appliance, as well as its individual shut-off valve,
must be disconnected from the gas supply piping
system during any pressure testing of the system at
test pressures in excess of 1/2 PSIG (3.5 kPa).
When checking appliance regulator function, make
certain pressure of natural gas supply is between 6
and 14 inches of water column or, if converted for LP
gas, between 11 and 14 inches.
THE PRESSURE TESTING SHOULD BE
PERFORMED BY MEANS OF THE INJECTOR
THREAD ZONE
Figure 14.
Pressure Test Method
Remove grate and burner cap
Remove aluminum gas spreader
Temporarily remove the injectors
Connect the pressure Test instrument into injector
holder thread zone (M6x0,75)
Check if the cooktop has the correct pressure
Fix the injector removed for testing and replace
the parts in the right position.
Gas test inlet
Thread
Cooktop & Installation Manual
014
13
Model COGB
ENGLISH

Advertisement

Table of Contents
loading

Table of Contents