Brush Inspection And Replacement; Adjusting Table Level; Remove Gib Bolts; Remove Blade - Craftsman 351.217220 Operator's Manual

12" thickness planer
Table of Contents

Advertisement

Available languages

Available languages

--2_°
A
B
Figure 14 - Remove Blade Guard
Carefully turn cutterhead by hand towards you until
bolts are accessible.
Loosen and remove six bolts from gib (C).
Replace gib and align the holes on the gib with
holes on the blade using magnets.
Secure gib to cutterhead using six bolts removed
earlier.
Carefully turn cutterhead by hand until the other
blade is accessible.
Remove gib and blade as mentioned earlier.
Replace with new blade and replace gib and secure
it as mentioned earlier.
Replace blade guard and secure it using two bolts.
BRUSH INSPECTION
AND REPLACEMENT
WARNING:
Turn planer off and disconnect from power
source. Brush life depends on amount of load on motor.
Regularly inspect brushes after 100 hours of use.
Brushes are located on either side of planer motor.
Loosen brush holder (A) and gently remove brush
from motor.
NOTE: Brushes are located on both front and rear
sides of planer.
Replace brushes if spring (B) is damaged.
Replace brushes if carbon (C) is worn.
Replace brushes and tighten brush holder.
Figure 15 - Remove Gib Bolts
Remove gib using magnet provided.
NOTE: Magnet can be easily disengaged from gib by
tilting them to left or right.
CAUTION:
Blade edges are extremely sharp. Keep fin-
gers away from blades at all times.
Blade is located in position by two pins. Gently lift
old blades from cutterhead using magnets. Do not
make contact with the blade using fingers. Use mag-
net only.
Magnet _
_
Gib
Pin
\
Cutterhead
Figure 16- Remove Blade
Reverse or replace blade and carefully position it on
the two pins using magnets.
\
Figure 17- Replace Brushes
B
ADJUSTING
TABLE LEVEL
Refer to Figures 19 and 20, pages 14 and 16.
The planer will produce uneven depth of cut (tapered
cut) if the rollercase (Fig. 20, Key No. 34) is not parallel
with the base (Fig. 19, Key No. 35). To restore paral-
lelism of the rollercase with the base:
Using a test piece, measure the height of the taper.
• Turn planer off and disconnect form power source.
Lay planer carefully on it's side so that bottom side
of the base is exposed.
Loosen socket head bolt holding idler bracket (Fig.
19, Key Nos. 46 and 44). Loosen chain.
Rotate lead screws (Figure 19, Key Nos. 30 and 32)
as needed. Each turn of screw by one sprocket tooth
will move that corner of rollercase by about 0.006".