Enterasys RoamAbout RBT-4102 Installation Manual page 16

Enterasys wireless access point installation guide
Hide thumbs Also See for RoamAbout RBT-4102:
Table of Contents

Advertisement

Compliances
SAFETY COMPLIANCE
Power Cord Safety
Please read the following safety information carefully before installing the access point:
WARNING: Installation and removal of the unit must be carried out by qualified personnel only.
The unit must be connected to an earthed (grounded) outlet to comply with international
safety standards.
Do not connect the unit to an A.C. outlet (power supply) without an earth (ground)
connection.
The appliance coupler (the connector to the unit and not the wall plug) must have a
configuration for mating with an EN 60320/IEC 320 appliance inlet.
• The socket outlet must be near to the unit and easily accessible. You can only remove power
from the unit by disconnecting the power cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC
60950. The conditions are only maintained if the equipment to which it is connected also
operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection
point labelled Neutral, connected directly to earth (ground).
Impédance à la terre
Important! Before making connections, make sure you have the correct cord set. Check it
(read the label on the cable) against the following:
U.S.A. and Canada
Denmark
Switzerland
U.K.
xiv
supplies. If your supplies are of IT type, this unit must be
Power Cord Set
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A.
The attachment plug must be an earth-grounding type with NEMA
5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.
The supply plug must comply with Section 107-2-D1, Standard
DK2-1a or DK2-5a.
The supply plug must comply with SEV/ASE 1011.
The supply plug must comply with BS1363 (3-pin 13 A) and be fitted
with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of type
HO3VVF3GO.75 (minimum).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents