Ericsson C3 MAESTRO LBI-39101A Installation And Setup Manual
Ericsson C3 MAESTRO LBI-39101A Installation And Setup Manual

Ericsson C3 MAESTRO LBI-39101A Installation And Setup Manual

Console system with enhanced audio enclosure
Table of Contents

Advertisement

Quick Links

INSTALLATION AND SET-UP MANUAL
C3 MAESTRO
WITH ENHANCED AUDIO ENCLOSURE
GENERAL.......................................................................................................................................................
PERSONAL COMPUTERS ...................................................................................................................
Hardware.............................................................................................................................................
Operating System Software.................................................................................................................
BOARD SET-UP .............................................................................................................................................
ENHANCED AUDIO ENCLOSURE.....................................................................................................
Audio System Board ...........................................................................................................................
Mic Audio ALC Enable/Disable DIP Switch (S1).......................................................................
Digital Pots Settings ....................................................................................................................
SPEAKER ASSEMBLY..........................................................................................................................
Speaker Amp Board............................................................................................................................
Minimum Volume Level DIP Switch (SW1 Position 1)..............................................................
Maximum Volume Level DIP Switch (SW1 Position 2) ............................................................. 10
RS-422 BOARD........................................................................................................................................ 11
INTERCONNECTING THE EQUIPMENT ................................................................................................ 11
CEC/IMC INTERCONNECTIONS....................................................................................................... 11
Control Data Link ............................................................................................................................... 12
Overview ..................................................................................................................................... 12
RS-422 Interfacing (Co-Located Hook-Ups)............................................................................... 12
Interconnections) ......................................................................................................................... 13
Audio Links ........................................................................................................................................ 14
PERSONAL COMPUTER...................................................................................................................... 18
PC-To-Enhanced Audio Enclosure Serial Data Interconnect Cable ................................................... 18
Standard PC Keyboard........................................................................................................................ 18
Video Display Monitor ....................................................................................................................... 18
ENHANCED AUDIO ENCLOSURE..................................................................................................... 18
Dispatch Keyboard ............................................................................................................................. 18
Desk Mic (if used) ............................................................................................................................. 18
Headset Jacks (if used) ....................................................................................................................... 18
Boom/Gooseneck Mic (if used) .......................................................................................................... 19
Footswitches (if used) ......................................................................................................................... 19
Speakers (if used)................................................................................................................................ 19
Recorder Outputs (if used).................................................................................................................. 20
Paging Input (if used).......................................................................................................................... 20
Relay Outputs (if used) ....................................................................................................................... 21

TABLE OF CONTENTS

LBI-39101A
Page
5
6
6
6
6
6
6
6
7
7
7
7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C3 MAESTRO LBI-39101A and is the answer not in the manual?

Questions and answers

Summary of Contents for Ericsson C3 MAESTRO LBI-39101A

  • Page 1: Table Of Contents

    LBI-39101A INSTALLATION AND SET-UP MANUAL ™ C3 MAESTRO CONSOLE SYSTEM WITH ENHANCED AUDIO ENCLOSURE TABLE OF CONTENTS Page GENERAL............................... PERSONAL COMPUTERS ........................Hardware............................. Operating System Software......................... BOARD SET-UP ............................. ENHANCED AUDIO ENCLOSURE..................... Audio System Board ........................... Mic Audio ALC Enable/Disable DIP Switch (S1)............... Digital Pots Settings ........................
  • Page 2 Table 12 – CEC/IMC Audio Lines (female DB-25 labeled "LINES 1-4") ........30 Table 13 – Call Director (female DB-9 labeled "CALL DIR")............32 Table 14 – Boom/Gooseneck Microphone (female DB-9 labeled "B/G MIC") ......... 32 Table 15 – Desk Microphone (female DB-9 labeled "DESK MIC")..........32 Copyright© February 1995, Ericsson Inc.
  • Page 3 LBI-39101 TABLE OF CONTENTS Page Table 16 – Operator Headset (female DB-9 labeled "OPER H/S") ..........32 Table 17 – Supervisor Headset (female DB-9 labeled "SUPER H/S") ..........33 Table 18 – Select Speaker (male DB-9 labeled "SEL SPKR") ............33 Table 19 –...
  • Page 4 LBI-39101 This Page Intentionally Blank Copyright© February 1995, Ericsson Inc.
  • Page 5: General

    GENERAL LBI-39101 GENERAL C3 Maestro (PC) application software version 5.0x (344A3922G12) The intent of this manual is to guide field installation and maintenance personnel through the installation and set- Enhanced Audio Enclosure firmware version 1.00 ® up of an EDACS C3 Maestro™...
  • Page 6: Personal Computers

    LBI-39101 BOARD SET-UP PERSONAL COMPUTERS IMPORTANT NOTE In most cases, changes to the factory DIP switch In most cases, the Personal Computer (PC) used with and digital pot settings ARE NOT REQUIRED. the C3 Maestro console is delivered with its hard disk drive ®...
  • Page 7: Digital Pots Settings

    BOARD SET-UP LBI-39101 numeric keypad) keys. "Digital Pot Number: ?" Digital Pots Settings is displayed in the lower left-hand side of the C3 To provide computer-controlled level settings, the Maestro's display. Enhanced Audio Enclosure's audio input and audio output circuits incorporate 256-position digitally-controlled...
  • Page 8: Table 3 - Digital Pots

    LBI-39101 BOARD SET-UP Table 3 – Digital Pots AUDIO TYPICAL ENHANCED AUDIO ENCLOSURE AUDIO CIRCUIT LOCATED IN / SYSTEM BD. SETTING ADJUSTS * POT NO. Call Director Input Adjusts level of telephone line audio from Call Director. Affects audio levels to operator/supervisor headsets, select speaker, select recorder and line output to CIM line input (to radio) during Call Director radio patch operations.
  • Page 9 BOARD SET-UP LBI-39101 Table 3 – Digital Pots (Continued) AUDIO TYPICAL ENHANCED AUDIO ENCLOSURE AUDIO CIRCUIT LOCATED IN / SYSTEM BD. SETTING ADJUSTS * POT NO. Line 2 Input Adjusts level of line 2 input audio from CIM line 2 output. Affects audio level to unselect audio output devices such as unselect speaker 1 and unselect recorder.
  • Page 10: Maximum Volume Level Dip Switch (Sw1 Position 2)

    LBI-39101 BOARD SET-UP Table 3 – Digital Pots (Continued) AUDIO TYPICAL ENHANCED AUDIO ENCLOSURE AUDIO CIRCUIT LOCATED IN / SYSTEM BD. SETTING ADJUSTS * POT NO. Unselect Speaker 2 Output Adjusts level of audio applied to the second unselect speaker (unselect speaker 2). This pot is not used as a volume control.
  • Page 11: Rs-422 Board

    INTERCONNECTING THE EQUIPMENT LBI-39101 RS-422 BOARD Enhanced Audio Enclosure-to-Boom/Gooseneck PTT and Monitor Switches Most PCs used within the C3 Maestro console application are equipped with a plug-in RS-422 capable Enhanced Audio Enclosure-to-Footswitches board for serial data interfacing to the CIM within the Enhanced Audio Enclosure-to-Speaker...
  • Page 12: Control Data Link

    LBI-39101 INTERCONNECTING THE EQUIPMENT Switch Customer-Specific System Documentation model number is 3PXOCC1A (part number 344A3927P38). maintenance manual, LBI-38939 for sample print-outs and Subsequent to the writing of this manual, additional boards complete print-out explanations. may be approved. Factory-installed plug-in RS-422 boards are configured Control Data Link correctly before the PC ships from the factory.
  • Page 13: Rs-232 Interfacing (Remote Console Hook-Ups Via 4-Wire Modems And Rs-232 Interconnections)

    INTERCONNECTING THE EQUIPMENT LBI-39101 Table 4 – Cable 19B804083P3 Color Coding RS-422 TX- (WHITE/BLUE) TYPICAL RS-422 RX- WIRE (WHITE/ORANGE) RS-422 CONSOLE CEC/IMC COLOR PORT RS-422 CONNECTION SHIELD SIGNAL GROUND (Also see (WHITE/GREEN) DB-25 SIGNAL IDENTIFI- page 36) PIN NO. CATION * cable shield none ** CRT 01 RX- DATA...
  • Page 14: Audio Links

    LBI-39101 INTERCONNECTING THE EQUIPMENT 2-Wire/4-Wire = 4 Wire Speaker Options TX Level = (as required; use -15 dBm if line loss is 0 dB) Volume Control = Low Dial Backup = Manual Control = On Until Carrier Detect Loop Back Time = 15 minutes Audio Links Dial Line = RJ11 Audio Concentrator Cards at the back of the CEC/IMC...
  • Page 15: Table 5 C3 Maestro-To-Cec/Imc Audio Line Requirements

    INTERCONNECTING THE EQUIPMENT LBI-39101 If cable 19B804083P2 is not used, fabricate an LINES equivalent cable, less unnecessary pairs, to interconnect the required pairs between the Enhanced Audio Enclosure's "LINES 1-4" DB-25 connector and the appropriate CEC/IMC Audio Concentrator Card's pins or CEC/IMC punch LINE 1 IN HI/+ block's terminals.
  • Page 16: Figure 6A Cec/Imc-To-C3 Maestro Interconnections (Co-Located)

    LBI-39101 INTERCONNECTING THE EQUIPMENT Figure 6A CEC/IMC-To-C3 Maestro Interconnections (Co-Located)
  • Page 17: Figure 6B Cec/Imc-To-C3 Maestro Interconnections (Remote And/Or Rs-232)

    INTERCONNECTING THE EQUIPMENT LBI-39101 Figure 6B CEC/IMC-To-C3 Maestro Interconnections (Remote And/Or RS-232)
  • Page 18: Personal Computer

    LBI-39101 INTERCONNECTING THE EQUIPMENT PERSONAL COMPUTER Dispatch Keyboard The Dispatch Keyboard interfaces to the console system PC-To-Enhanced Audio Enclosure Serial Data via the Enhanced Audio Enclosure. This keyboard's part Interconnect Cable number P29/7590182003 (350A1371P17). sometimes referred to as the "custom keyboard". The PC-to-Enhanced Audio Enclosure RS-232 serial data link uses cable P29/5010150000 (350A1371P29).
  • Page 19: Boom/Gooseneck Mic (If Used)

    INTERCONNECTING THE EQUIPMENT LBI-39101 NOTE NOTE Microphone priority is (highest to lowest): All boom and gooseneck mic connectors (male DB- 9) must have pins 2 and 3 jumpered together so the Supervisory Headset Mic (highest) sense circuit will be active when the mic is á...
  • Page 20: Recorder Outputs (If Used)

    LBI-39101 INTERCONNECTING THE EQUIPMENT assembled with one amplified speaker in the far left-hand RECORDER position (select speaker), one amplified speaker in the far WIRE SECURING SCREWS LOCATED ON TOP right-hand position (unselect speaker) and blank panels WIRE ATTACHMENT: installed in the two center positions. Four-speaker consoles 1.
  • Page 21: Relay Outputs (If Used)

    INTERCONNECTING THE EQUIPMENT LBI-39101 Relay Outputs (if used) Call Director (if equipped) Form-C relay contacts (single-pole double-throw) are As shown in Figure 1, all C3 Maestro-to-Call Director available from the Enhanced Audio Enclosure for external interconnections at the console are made at the Enhanced Audio Enclosure's connector labeled "CALL DIR".
  • Page 22: Table 7 Enhanced Audio Enclosure-To-Cec/Imc Call Director Audio Signal Descriptions

    LBI-39101 INTERCONNECTING THE EQUIPMENT Table 7 Enhanced Audio Enclosure-To-CEC/IMC Call Director Audio Signal Descriptions INPUT / TYPE OUTPUT Patched Radio Input Radio audio from CIM TX channel/line 4. During a CD telephone patch, this audio is heard at the telephone. CD/Operator Mic Output Telephone/operator mic audio to CIM RX channel/line 4.
  • Page 23: Equipment Room Grounding

    AUDIO TOWER REPLACEMENT LBI-39101 EQUIPMENT ROOM GROUNDING Disconnect large PC-to-Audio Tower interconnect cable connecting the Audio Tower to Proper grounding techniques should be observed in the Logic Board installed in the PC. This cable is order to protect the equipment and service personnel from no longer needed.
  • Page 24: Table 9 - Dispatch Keyboard Cable Color Coding

    LBI-39101 AUDIO TOWER REPLACEMENT Application Software Installation Table 9 – Dispatch Keyboard Cable Color Coding If necessary, obtain C3 Maestro application software V5.0 (or later). MALE CABLE DB-9 PIN WIRE Install this software on PC's hard disk drive in NUMBER COLOR accordance with the supplied instructions.
  • Page 25: Power-Up Procedure

    POWER-UP PROCEDURE LBI-39101 14. Call Director Existing (old) speakers and the Volume Controller Box were disconnected in step 1. Install and cable If the Audio Tower was connected to a Call the new Speakers Assemblies (desktop or rack- Director, connect the male DB-9 connector on the mount) to the Enhanced Audio Enclosure in cable from the Call Director (disconnected in step 1 accordance with the subsection entitled "Speakers...
  • Page 26: Software Installation And Set-Up Procedure

    LBI-39101 SOFTWARE INSTALLATION AND SET-UP PROCEDURE SOFTWARE INSTALLATION AND COM1 is disabled by setting "Serial Port A" to "Off". This disables the computer's main board SET-UP PROCEDURE COM1 serial port so the plug-in RS-422 board used for CEC/IMC control data interfacing can be set to COM1 without conflicting.
  • Page 27: Autoexec.bat File Contents

    SOFTWARE INSTALLATION AND SET-UP PROCEDURE LBI-39101 AUTOEXEC.BAT File Contents Serial Ports' Settings Contents of the AUTOEXEC.BAT file located in the Normally, the PC's COM1 serial port is utilized for root directory (C:\) are as follows. Changes are not CEC/IMC control data interfacing. The baud rate of this port recommended: may be set to operate at 19,200 or 9600.
  • Page 28: Running The C3 Maestro Application Program

    LBI-39101 SOFTWARE INSTALLATION AND SET-UP PROCEDURE "STEP CONSOLE CONFIGURATION" If using CEC/IMC firmware version 2.x (and LBI-38938 for details. earlier), set the Call Director ID number from the Editor program's "CONFIGURATION DATA" form. Save changes to the hard disk drive. See LBI- NOTE NOTE 39056 for complete details.
  • Page 29: System Manager Database Uploads

    SOFTWARE INSTALLATION AND SET-UP PROCEDURE LBI-39101 Set-Up And Troubleshooting maintenance manual, Console Privilege Lists LBI-38938. "User Profile Each console must be sent its privilege list from the Successfully Written..." message must CEC/IMC Manager as follows: be received before continuing. From the CEC/IMC Manager's "CEC/IMC MOM System Manager Database Uploads Options"...
  • Page 30: Software Installation And Upgrades

    LBI-39101 ENHANCED AUDIO ENCLOSURE CONNECTOR PIN-OUTS Table 12 – CEC/IMC Audio Lines defining the event for input or output operation (female DB-25 labeled "LINES 1-4") (event type) defining the event’s CEC/IMC Controller Board NAME USE * utilized (device type and device assignment number) and the I/O bit number used on this LINE_1_IN+ Line 1...
  • Page 31: Figure 11 - Enhanced Audio Enclosure Rear Panel Connectors

    ENHANCED AUDIO ENCLOSURE CONNECTOR PIN-OUTS LBI-39101 See Table 24 See Table 23 See Table 25 See Table 22 See Table 21 See Table 20 See Table 19 See Table 19 See Table 19 See Table 18 See Table 17 See Table 16 See Table 15 See Table 14 See Table 13...
  • Page 32: Table 13 - Call Director (Female Db-9 Labeled "Call Dir")

    LBI-39101 ENHANCED AUDIO ENCLOSURE CONNECTOR PIN-OUTS Table 13 – Call Director Table 15 – Desk Microphone (female DB-9 labeled "CALL DIR") (female DB-9 labeled "DESK MIC") NAME NAME output; no connection ON_HOOK_NO see pin 6 and Table 8 PS_GND_IN ground for pin 3 CD_HOOK_SENSE_IN monitor PTT (enable) MONITOR_PTT_IN...
  • Page 33: Table 17 – Supervisor Headset (Female Db-9 Labeled "Super H/S")

    ENHANCED AUDIO ENCLOSURE CONNECTOR PIN-OUTS LBI-39101 Table 17 – Supervisor Headset Table 19 – Unselect Speakers –Three Total (female DB-9 labeled "SUPER H/S") (male DB-9 labeled "UNSEL SPKRx"*) NAME NAME no connection UNSELECT_SPEAKER_ high-impedance x_OUT speaker audio output no connection USEL_SPEAKER_ ground for pin 1 headset connected/not...
  • Page 34: Table 21 – Supervisor Footswitch (Female Db-9 Labeled "Super Ft. Sw.")

    LBI-39101 ENHANCED AUDIO ENCLOSURE CONNECTOR PIN-OUTS Table 21 – Supervisor Footswitch Table 23 – Personal Computer RS-232 Input/Output (female DB-9 labeled "SUPER FT. SW.") (female DB-9 labeled "PC") NAME NAME no connection no connection PS_GND_IN ground for pins 4 & 6 TX_PC_DATA_OUT serial data output no connection...
  • Page 35: Table 25 – Relay Connections (18-Position Terminal Block Labeled "Relays")

    ENHANCED AUDIO ENCLOSURE CONNECTOR PIN-OUTS LBI-39101 Table 25 – Relay Connections Table 26 – Pager Input (18-position terminal block labeled "RELAYS") (4-position terminal block labeled "PAGING") ACTIVATION TERMINAL NAME TERMINAL NAME* METHOD PAGER_IN+ balanced RELAY_1_NO console audio input PAGER_IN- RELAY_1_C PAGER_PTT_IN PTT (enable) input (momentary action)
  • Page 36: Control Data Cable (100-Foot) 19B804083P3

    LBI-39101 CABLE ASSEMBLY DIAGRAM CONTROL DATA CABLE (100-FOOT) 19B804083P3 (Made from 19B804083 Sh. 4, Rev. 3)
  • Page 37 CABLE ASSEMBLY DIAGRAM LBI-39101 AUDIO CABLE (100-FOOT) 19B804083P2 (Made from 19B804083 Sh. 3, Rev. 3)
  • Page 38 Ericsson Inc. Private Radio Systems Mountain View Road Lynchburg, Virginia 24502 1-800-528-7711 (Outside USA, 804-528-7711) Printed in U.S.A.

Table of Contents