TROUBLESHOOTING
Problem
No AC output
is available,
but
generator
is running.
Cause
I.
One of the circuit breakers is
open.
2.
Fault in generator.
3.
Poor connection or defective
cord set.
4.
Connected device is bad.
Correction
I.
Reset circuit breaker.
2.
Contact Authorized
service
facility.
3.
Check and repair.
4.
Connect another
device that is in
good condition.
I.
Short circuit in a connected load.
I.
Disconnect
shorted electrical
Generator
runs good at no-load
load.
but "bogs"
down" when loads are
2.
Generator
is overloaded.
2.
See "Don't Overload
Generator".
connected.
3.
Shorted generator
circuit.
3.
ContactAuthorized
service
facility.
Generator
will not start; or starts
Low oil level.
Fill crankcase to proper level or place
and runs rough,
generator
on level surface.
I.
Out of fuel.
I.
Fill fuel tank.
Generator
shuts down during
2.
Low oil level.
2.
Fill crankcase to proper level or
operation,
place generator
on level surface.
Generator
lacks power.
Load is too high.
See "Don't Overload
Generator".