PRODUCT DATASHEET
ENERGIZER AC13
(top view) (bottom view)
Industry Standard Dimensions
mm (inches)
3.00 (0.118)
Minimum
1.35R (0.053)
Typical
7.90 (0.311)
7.55 (0.297)
Typical Discharge Characteristics
Schedule: 16 hours/day
Typical Drain @ 1.3V:
1.3 & 0.87 milliamperes
Load: 1K & 1.5K ohms
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0
60
120
Service, Hours
Simulated Application Test
Typical Performance at 21°C (70°F) & 50% RH
Schedule:
Typical Drains:
at 1.3V
(milliamperes)
16 Hours/Day
16 Hours/Day
0.87
This data sheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4503F
0.38 (0.015)
Minimum
5.40 (0.213)
5.00 (0.197)
1K
1.5K
180
240
300
360
Load
Cutoff
0.9V
(ohms)
(hours)
1.3
1,000
215
1,500
322
Important Notice
Specifications
Chemical System:
Zinc Air (ZnO
Tab Color:
Orange
Designation:
ANSI-7000ZD, IEC-PR48
Nominal Voltage:
1.4 Volts
Typical Capacity:
280 mAh (to 0.9 volts)
(Rated at 1.5k ohms at 21°C/50% RH)
Typical Weight:
0.8 grams (0.03 oz.)
Typical Volume:
0.03 cubic centimeters (0.02 cubic inch)
Impedance
The total opposition that a battery offers to the flow of
alternating current. Impedance is a combination of resistance
and reactance.
The typical impedance of these cells on open circuit and during
useful discharge varies from 5-20 ohms. This applies over a
frequency range of 40-5,000 hertz at the current drains shown
below.
Impedance vs. Frequency
20
16
12
8
4
0
0.1
1
10
Frequency (Hz)
Impedance vs. Depth of Discharge
25
20
15
10
40 Hz
5
1K Hz
0
0%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Depth of Discharge
1-800-383-7323 USA/CAN
www.energizer.com
)
2
00% DoD
25% DoD
50% DoD
80% DoD
100
1000
10000 100000
Page 1 of 1