Instructions for Installation (cont'd)

Filling the Water Heater

To fill the water heater with water:
1. Close the water heater drain valve by turning the
handle to the right (clockwise). The drain valve is on
the lower front of the water heater.
2. Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left
open when the water heater is in use.
3. To insure complete filling of the tank, allow air to exit
by opening the nearest hot water faucet. Allow water
to run until a constant flow is obtained. This will let air
out of the water heater and the piping.
CAUTION
Never use this water heater unless it is completely full of
water. To prevent damage to the tank and heating element, the
tank must be filled with water. Water must flow from the hot
water faucet before turning "ON" power.
4. Check all new water piping for leaks. Repair as needed.

Wiring Diagrams

STANDARD WIRING FOR
2 WIRE LEAD WATER HEATERS
NON-SIMULTANEOUS OPERATION
240 VOLT DOUBLE ELEMENT
TO ELECTRIC
POWER SUPPLY
BLACK
UPPER E.C.O. &
THERMOSTAT
UPPER
ELEMENT
RED
LOWER
HEATING ELEMENT
WIRING FOR 3 WIRE LEAD WATER HEATERS
NON-SIMULTANEOUS OPERATION 240 VOLT
DOUBLE ELEMENT
YELLOW
UPPER
HEATING ELEMENT
LOWER
HEATING ELEMENT
Note: Some Lower Hi-Temp Limit switches may have 4
terminals. Use only the 2 terminals on left.
13
STANDARD WIRING FOR
SINGLE ELEMENT 240 VOLT
TO ELECTRIC POWER SUPPLY
BLACK
RED
HEATING ELEMENT
JUNCTION
BOX