Specification; Fireplace Dimensions - White Mountain Hearth DVP42FP Installation Instructions And Owner's Manual

The tahoe direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

21759-6-0608
SPECIFICATIONS
Input Btu/hr Maximum
Btu/hr Minimum (millivolt only)
KWH (Maximum)
(Minimum)
NAT.
Orifice
Air Shutter Opening
LP
Orifice
Air Shutter Opening
Height without standoff
Width
Depth
Gas Inlet Shutoff Valve (Pipe)
Remote Control Options
& Accessories
FRBC
FRBTC
TMW
TRW
FWS-1

FIREPLACE DIMENSIONS

J
H
DVP42
28,000
19,000
8.2
5.5
#38 (.1015)
P-203
1/8"(3.2mm)
#52 (.0635")
P-213
FULL OPEN
34 3/4"(3.2mm)
43"(1092mm)
19
7/8"(505mm)
1/2 NPT
Description
Millivolt Batt. Remote ON/OFF
Millivolt Batt. Remote T-Stat
Millivolt WIRELESS Wall Thermostat
Millivolt REED SWITCH Wall Thermostat
Direct Ignition/Millivolt Wall Switch
RIGHT SIDE VIEW
K
Figure 1
DVP48
30,000
20,500
8.8
NOTE: Air shutter settings
6.0
are factory minimum
settings. Some venting
c o n f i g u r a t i o n s m a y
#37 (.1040)
require minor air shutter
P-213
adjustments for optimum
1/8"(3.2mm)
performance.
1.65MM
P-250
FULL OPEN
34
3/4"(3.2mm)
49"(1245mm)
19
7/8"(505mm)
1/2 NPT
DVP42
DVP48
A
43"
49"
1092mm
1245mm
B
40"
46"
1016mm
1168mm
C
25 1/16"
25 1/16"
636 mm
636 mm
D
37 5/8"
37 5/8"
956 mm
956 mm
E
34 3/4"
34 3/4"
883 mm
883 mm
F
19 7/8"
19 7/8"
505 mm
505 mm
G
26"
26"
660 mm
660 mm
H
7 1/8"
7 1/8"
181 mm
181 mm
I
26 1/2"
32 1/2"
826 mm
826 mm
J
13 1/4"
16 1/4"
337 mm
413 mm
K
12 3/4"
12 3/4"
324 mm
324 mm