White Mountain Hearth DVP42FP Installation Instructions And Owner's Manual page 13

The tahoe direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

Flush Wall Installation
FINISHED WALL
3! OF NON-COMBUSTIBLE MATERIAL
FRONT TRIM OR NON-
COMBUSTIBLE MA TERIAL
(INSTALLA TION IS OPTIONAL)
Combustible Surround Installation
2 X 4
HEADER
STAND OFF
21759-6-0608
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
Figure 12
MANTELSHELF
COMBUSTIBLE SURROUND
FINISHED WALL
3! OF NON-COMBUSTIBLE MATERIAL
FRONT TRIM OR NON-COMBUSTIBLE
MATERIAL (INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED WALL AND
UNIT SEALED WITH 300° F 149
SEALANT
MATERIAL (SEALANT IS OPTIONAL)
Figure 13
Attention: Cold climate installation recommendation:
When installing this unit against a non-insulated exterior
wall, it is recommended that the outer walls be insulated to
conform to applicable insulation codes.
Vent Runs (Figures 14, 15, 16, 17 and 18)
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for the
appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact all
four (4) perimeter edges on the bottom of the unit.
VERTICAL, 90° ELBOW WITH HORIZONTAL
DVP42, 48
49 ½"(126 mm)
TO BOTTOM
OF UNIT
° C
TERMINATION
Figure 14
VENT CAP/
THIMBLE
/
THIMBLE
Page 13