NEC MultiSync V423 Manual page 60

External control
Hide thumbs Also See for MultiSync V423:
Table of Contents

Advertisement

***Following command also can be used for to keep backward compatibility, in order to
write the setting of the Schedule.
1) The controller requests the monitor to write Schedule.
Header
SOH-'0'-Monitor ID-'0'-'A'-'1'-'6'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'6'(31h, 36h): Message length.
Message
STX (02h): Start of Message
'C'-'2'-'1'-'4' (43h, 32h, 31h, 34h): Schedule writes command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data
PG: Program No.
ON_HOUR: Turn on time (hour)
ON_MIN: Turn on time (minute)
OFF_HOUR: Turn off time (hour)
OFF_MIN: Turn off time (minute)
INPUT: Timer input
WD: Week setting
STX-'C'-'2'-'1'-'4'-PG-ON HOUR-ON MIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-ETX
Ex.) If Monitor ID is '1', specify 'A'.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn't set.
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59 (=3Bh)
'3'-'C'(33h, 43h): Off timer isn't set.
'0'-'0'(30h, 30h): DVI
'0'-'1'(30h, 31h): VGA
'0'-'2'(30h, 32h): RGB/HV
'0'-'3'(30h, 33h): DVD/HD1
'0'-'4'(30h, 34h): VIDEO
'0'-'5'(30h, 35h): S-VIDEO
'0'-'7'(30h, 37h): (Works on last memory)
* Please select active input on your system (setting).
* If you select inactive input here, the input change execution will be ignored.
bit 0: Monday
bit 1: Tuesday
bit 2: Wednesday
Message
(60/72)
Check code
Delimiter
BCC
CR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents