Ventilation requirements
Ventilation heightS
It is essential that all maximum or minimum dimensions
are strictly maintained, as the performance of the refrigerator
is dependent on adequate flow of air over the rear of
the refrigerator.
Minimum ventilation heights
Roof vent and
lower side vent
inches
RM2351
31
RM2354
RM2451
37-3/4
RM2454
RM2551
44-1/2
RM2554
DM2652
DM2662
57-3/4
DM2663
DM2852
DM2862
63-3/4
DM3862
NDM1062
NDR1292
65
A
Minimum
ventilation
height
Condenser
B
Minimum
Condenser
ventilation
height
Upper and lower
A
side vent
mm
inches
mm
787
34
864
960
1130
1465
1620
1651
The upper vent
should be centered
over the condenser
coil at the back of
the refrigerator.
cleaRaNces
Minimum clearances (in inches) to combustible materials:
Top (G)
Side (K)
Bottom (L)
Rear (M
)
1
B
1
The distance between the rearmost part of the refrigerator and the wall
behind it.
M
SIDe vIew wITh DUCT SySTeM
DM2852, DM2862, DM3862 & NDM1062
Air channel
For installation instructions of the Air Channel, please refer to
"
INSTAllATIoN oF AIR ChANNEl
- 5 -
0
0
0
0 / 1
(RM2351 &
RM2354)
G
K
L
M
", Rev. 825129100 or later.