REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION.
RM 2554
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WARNING: Improper installation,
adjustment, alteration,service or
maintenance can cause injury or
property damage. Refer to this
manual. For assistance or additional
information consult a qualified
installer, service agency or the gas
supplier.
USA
Service Office
The Dometic Corporation
509 South Poplar Street
LaGrange, IN 46761
Phone: 219-463-4858
822 70 92-00 (French 3109260.004)
RM2554
Corporate Office
2320 Industrial Parkway Elkhart, IN 46515
For Service Center Assistance
Call: 800-544-4881
INSTALLATION AND
OPERATING INSTRUCTIONS
Contents:
Installation
Operating Instructions
Maintenance & Service
Cet appareil doit être réparé
seulement par un réparateur
autorisé. Modification de
l'appareil pourrait être
extrèmement dangeruse, et
pourrait causer mal ou mort.
Page
4
8
12
AVIS
CANADA
Dometic Distribution Inc.
866 Langs Drive
Cambridge,Ontario
N3H 2N7 Canada
Phone: 519-653-4390

Advertisement

loading
Need help?

Need help?

Do you have a question about the Americana RM 2554 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dometic Americana RM 2554

  • Page 1 Corporate Office 2320 Industrial Parkway Elkhart, IN 46515 For Service Center Assistance CANADA Service Office Call: 800-544-4881 Dometic Distribution Inc. The Dometic Corporation 866 Langs Drive 509 South Poplar Street Cambridge,Ontario LaGrange, IN 46761 N3H 2N7 Canada Phone: 219-463-4858 Phone: 519-653-4390 822 70 92-00 (French 3109260.004)
  • Page 3 Heaters Reigniter Flue baffle Power module cover Protection cover Screw for protection cover Burner jet 12 Volt Terminal block Manual gas shutoff valve Inlet fitting Drain water hose Flexible cord FIG. 1 Refrigerator control panel LEGEND 3-WAY AMES Model 1. Main Power Button ON/OFF 2.
  • Page 4 CERTIFIED INSTALLATION INSTALLATION Certified installations require one roof vent and one GENERAL INSTRUCTION lower side vent. This appliance is designed for storage of foods For "Certified Vent System Kits" see page 15. and storage of frozen foods and making ice. For further information contact your dealer or distributor.
  • Page 5 VENTILATION HEIGHTS Refer to FIG. 3., page 4 Installation with roof Minimum ventilation vent and lower side vent heights in Refrigerator Inches RM 2554 44-1/2 1130 CLEARANCES FIG. 4 Minimum clearances in inches to combustible materials are: G: Top NOTE: Wood Strip K: Side MUST be in place Bottom 0...
  • Page 6 INSTALLING REFRIGERATOR IN ENCLOSURE NOTE: DO NOT install the appliance directly on carpeting. Carpeting must be removed or protected by a metal or wood panel be- neath the appliance which extends at least full width and depth of the appliance. NOTE: A wood strip must be in place across the upper opening of the enclosure.
  • Page 7 GAS CONNECTION Hook-up to the gas supply line is accomplished at the manual gas valve, which is furnished with a 3/8" SAE (UNF 5/8" -18) male flare connection. All completed connections should be checked for leaks with soapy water. ! WARNING DO NOT use a flame to check for gas leaks.
  • Page 8 ELECTRICAL CONNECTION OPERATING 120 Volts AC Connection INSTRUCTIONS The refrigerator is equipped with a three-prong (ground- IMPORTANCE OF LEVELING A ing) plug for your protection against shock hazards and REFRIGERATOR should be plugged directly into a properly grounded three-prong receptacle. DO NOT cut or remove the In an absorption refrigerator system, ammonia is lique- grounding prong from this plug.
  • Page 9 Refrigerator control panel START UP INSTRUCTIONS DC MODE Press the DC mode indicator button (2) to turn ON A. A continuous 12 volt DC supply must be available for the DC lamp (A). the electronic control to function. Press the TEMPERATURE SELECTOR button (4) B.
  • Page 10 Refrigerator control panel DESCRIPTION OF OPERATING DC MODE MODES When operating in the DC mode the DC mode indicator lamp (A) will be illuminated. All other mode lamps will be off. The DC mode overrides all other operating modes. AUTO MODE If one of the other operating modes is desired, the DC selector button (2) must be pressed to turn OFF the DC When operating in the AUTO mode, the AUTO mode...
  • Page 11 CLEANING HOW TO USE THE REFRIGERATOR Cleaning the refrigerator is usually done after it is defrosted or put into storage. To clean the interior liner FOOD STORAGE COMPARTMENT of the refrigerator, use lukewarm weak soda solution. The food storage compartment is completely closed and Use only warm water to clean the finned evaporator, unventilated, which is necessary to maintain the re- gaskets, ice trays and shelves.
  • Page 12 Refer to section INSTALLATION, page 4 to 8. 3. PERIODIC MAINTENANCE 1. CARTRIDGE HEATER To keep your Dometic refrigerator operating efficiently The heat necessary for the operation of an absorption and safely, periodic inspection and cleaning of several cooling unit is supplied by an electric heater mounted in components once or twice a year is recommended.
  • Page 13 C. Check the AMES control system by connecting/dis- 10. Reinstall burner, being careful that the end of the connecting 120 volt AC power, start/stop the engine, burner fits into the slot on the burner bracket. Check etc. Compare the operation with the operation to make sure slots are centered under the flue tube described in section Operating Instructions.
  • Page 14 17 37 39-07/9 Heater, 175W, 12V Conversion Kit Number. For further information, please 293 20 52-01/8 Thermocouple contact the Dometic Corporation listed on the front page. 293 25 75-01/8 Door shelf, lower 293 25 76-01/6 Door shelf, 3 pieces 293 26 21-01/0...
  • Page 15 CERTIFIED VENT SYSTEM KITS Refr. Model Components Drawing RM 2554 Roof Vent 3103633 Base 3103634 Cap (Both Required) Lower Side Vent 3102364 3102277 3102970 3102972 3101534 3101782 3101337 For further information, contact your dealer or distributor.
  • Page 16 RM 2554 MO-FO 9836...