Troubleshooting Guide; Communications Problems - Davis Instruments WeatherLink Getting Started Manual

For weather monitor ii, weather wizard iii and perception ii weather stations
Hide thumbs Also See for WeatherLink:
Table of Contents

Advertisement

Troubleshooting Guide

The following section answers some of the most commonly asked questions
about WeatherLink.
before contacting Technical Support (see page 13).

Communications Problems

Why can't the software communicate with the data logger and station?
If you are having trouble establishing communication between the weather
station and WeatherLink, start by checking the weather station's own diagnos-
tics. Remove all power to the weather station and then restart it by restoring
power (with the data logger still attached).
• You should hear three beeps, each of which occurs when the weather sta-
tion passes one of its diagnostic tests.
The first beep will occur immediately after power is restored; the second
beep will occur approximately 10 seconds later; the third beep will occur
approximately 20 seconds after the second beep. The first beep tells you
the processor is running. The second beep will be for the data logger (if
installed), and the third beep is for the display. If you do not hear one or
more of these beeps, contact Technical Support (see "Contacting Davis
Technical Support" on page 13). (You'll only hear two beeps if you don't
have the data logger installed.)
• If you hear all three beeps, See "Checking the Communications Port" on
page 10 for instructions on checking your serial port. Also check your
USB/serial port adapter to make sure it is correctly installed and operating
properly.
• Make sure you are using the DIN cable connector supplied with
WeatherLink for Mac OS X. Other adapters may not work.
• Check the Baud Rate setting on the data logger and in the Communications
Configuration dialog box in the software. Make sure they're set to the same
rate. Check the switch setting on the data logger. It will be set to either
1200 or 2400 Baud.
If you still cannot connect, check the following two potential problems. If
you have questions on how to proceed, contact the vendor or Davis Techni-
cal Support for your computer (see "Contacting Davis Technical Support"
on page 13).
Your serial port uses a non-standard device name.
Your serial port adapter is defective.
®
Please consult this guide and the on-line help files
Communications Problems
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Weatherlink for mac 7855

Table of Contents