vENT 4
Be sure vent
pipe is properly
connected
to prevent
escape
of
dangerous
flue gases which
could cause deadly
asphyxiation.
Chemical
vapor corrosion
of the flue and vent system
may occur
if air for combustion
contains
certain chemical
vapors.
Spray can
propellants,
cleaning
solvents,
refrigerator
and air conditioner
refrigerants,
swimming
pool
chemicals,
calcium
and sodium
chloride,
waxes,
bleach
and
process
chemicals
are typical
compounds
which
are potentially
corrosive.
Gas Pi iping
FIGURE 18,
The vent
pipe from the water
heater
must be no less than
the
diameter
of the draft hood outlet
on the water
heater
and must
slope upward
at least 1/4 inch per linear foot (21 mm per meter).
See Figure
19.
CHI NEY
FIGURE 19,
Fire and Explosion
Hazard
Do not use water
heater
with
any
gas
other
than
the
gas
shown onthe
rating plate.
Excessive
pressure
to
gas
control valve can cause serious
injury or death.
Turn
off
gas
lines
during
installation.
Contact
qualified installer
or
service agency.
All vent gases must be completely
vented
to the outdoors
of the
structure
(dwelling).
Install only the draft hood provided
with the
new water
heater and no other draft hood.
Vent pipes must be secured
at each joint with sheet metal screws.
There
must
be a minimum
of 6 inches
(153
mm) clearance
between
single
wall vent
pipe
and any
combustible
material.
Fill and
seal
any
clearance
between
single
wall
vent
pipe
and combustible
material
with
mortar
mix,
cement,
or other
noncombustible
substance.
For other
than
single
wall, follow
vent pipe manufacturer's
clearance
specifications.
To insure
a
tight fit of the vent pipe in a brick chimney,
seal around
the vent
pipe with mortar
mix cement.
Breathing
Hazard =Carbon
Monoxide
Gas
_*, [i2 °
-
Flue
gases
may
escape
if vent
pipe is not connected.
-
Do not store corrosive
chemicals
in vicinity ofwater
heater.
Chemical
corrosion
of flue
and
vent
system
can
cause
serious
injury or death.
-
Contact
a qualified
installer
or
service agency.
Breathing
carbon
monoxide
can cause brain damage
or death.
Always
read and understand
instruction
manual,
Make
sure
the gas
supplied
is the same
type
listed
on the
model
rating
plate.
The
inlet gas
pressure
must
not exceed
14 inch water column
(3.5kPa)
for natural
and propane
gas (L.P.)
gas.
The minimum
inlet gas pressure
listed on the rating plate
is for the purpose
of input
adjustment.
If the gas control
valve
is subjected
to pressures
exceeding
1/2 pound
per square
inch
(3.5kPa),
the damage
to the gas control
valve
could
result in a
fire or explosion
from leaking
gas.
If the main gas line shutoff serving
all gas appliances
is used, also
turn "OFF" the gas at each appliance.
Leave all gas appliances
shut "OFF"
until the water
heater
installation
is complete.
A gas line of sufficient
size
must
be run to the water
heater.
Consult
the current
edition
of National
Fuel
Gas Code
ANSI
Z223.1/NFPA
54 and your
gas supplier
concerning
pipe size.
There
must be:
A readily
accessible
manual
shut off valve
in the gas supply
line serving
the water
heater,
and
A drip leg (sediment
trap) ahead
of the gas control
valve
to
help prevent
dirt and foreign
materials
from entering
the gas
control
valve.
A flexible
gas connector
or a ground
joint
union
between
the shut off valve
and control
valve
to permit
servicing
of
the unit.
Be sure to check
all the gas piping for leaks before
lighting
the
water
heater.
Use a soapy water
solution,
not a match or open
flame.
Rinse
off soapy solution
and wipe dry.
Failure
to have
required
clearances
between
vent
piping
and
The minimum
inlet gas pressure
shown
on the rating
plate is that
combustible
material
will result
in a fire hazard,
which
will permit
firing
at the rated input.