READ AND UNDERSTAND THESE INSTRUCTIONS
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electric shock, turn off electricity at main power supply before proceeding.
Retain these instructions for maintenance reference.
INSTALLATION PROCEDURE FOR: LYTECASTER® 1000LV, 1000LVE1, & 1000LVE2 LOW VOLTAGE
CAUTION:
USE ONLY WITH REFLECTOR TRIMS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURER'S TRIMS
MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
CAUTION:
BEFORE INSTALLING FRAME-IN KIT AND REFLECTOR TRIM, READ ALL MARKINGS ON FRAME-IN KIT AND
REFLECTOR TO DETERMINE LAMP WATTAGE AND TYPE APPLICABLE FOR YOUR INSTALLATION.
WARNING— (RISK OF FIRE)
COMPARTMENT, NOR ABOVE FIXTURE IN SUCH A MANNER TO ENTRAP HEAT.
1. FRAME- IN AND WIRE-IN (Fig. A)
Fasten MOUNTING FRAME to wood joist. Line up bottom edge of
ADJUSTABLE MOUNTING BAR with bottom of wood joist (Fig. E). Wire to
supply leads. (For Cable, use built-in Cable Clamp in J-Box). WHITE
FIXTURE LEAD to NEUTRAL SUPPLY LEAD. BLACK FIXTURE LEAD to
HOT SUPPLY LEAD (120V). BARE FIXTURE WIRE to SUPPLY GROUND
(1000LV only). Use wirenuts (local hardware item). Place all electrical
connections in the J-BOX. Attach J-BOX COVER onto J-BOX.
NOTE:
ADJUSTABLE MOUNTING BARS can be extended for 24"
mounting. For suspended ceiling, make certain that the bottom of
MOUNTING FRAME is no higher than 1" above ceiling line (Fig. F)
2. CLOSE- IN (Fig. B)
Install plasterboard, or any other dry type ceiling, as required. Hole in board
must be cut either on the ground or after the board is nailed to the ceiling,
using MOUNTING FRAME opening as a cutting guide. (Make sure ROTO-
CLIPS are rotated out of hole area to be cut.) (Fig. G).
*Lightolier also offers a hole cutter (HC-356) that can be purchased
separately to assist with quick, clean trim installations. In this case, follow
the hole cutting directions supplied with HC-356.
3. SNAP-IN (Fig. C).
4. PUSH- UP (Fig. D).
NOTE:
For wet plaster ceiling, use Plaster Ring Accessory No.1959
(order separately).
SEE BACK PAGE FOR LAMPING INSTRUCTIONS
BEFORE INSTALLING LUMINAIRE.
DO NOT INSTALL INSULATION WITHIN 3 INCHES OF FIXTURE SIDES OR WIRING
SEE SEPARATE
REFLECTOR TRIM
INSTRUCTION SHEETS
FRAME-IN KITS
631 Airport Road, Fall River, MA 02720
INSTRUCTION SHEET NO.
IS:1000LV
B0607
Page 1 of 2
A
COMPANY

Advertisement

loading

Summary of Contents for Lightolier LYTECASTER 1000LV

  • Page 1 INSTALLATION PROCEDURE FOR: LYTECASTER® 1000LV, 1000LVE1, & 1000LVE2 LOW VOLTAGE FRAME-IN KITS CAUTION: USE ONLY WITH REFLECTOR TRIMS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURER’S TRIMS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD. CAUTION: BEFORE INSTALLING FRAME-IN KIT AND REFLECTOR TRIM, READ ALL MARKINGS ON FRAME-IN KIT AND REFLECTOR TO DETERMINE LAMP WATTAGE AND TYPE APPLICABLE FOR YOUR INSTALLATION.
  • Page 2 4. Insert LAMP RING with LAMP and GLASS LAMP GUARD back into SOCKET CUP. NOTE: 1. LOW VOLTAGE FIXTURES should be dimmed only with special dimmers intended specifically for that purpose. Use Lightolier Lytemode, Scenist, Crescendo VA, Neptune VA, Precision VA, Easyset VA, Sunrise VA, Radiant VA or equivalent products by others or variable autotransformers or electronic dimmers intended for use with low voltage fixtures.

This manual is also suitable for:

Lytecaster 1000lve1Lytecaster 1000lve2