Hitachi SJ200 Series Quick Reference Manual page 23

Hide thumbs Also See for SJ200 Series:
Table of Contents

Advertisement

Func.
Code
C041
Overload level setting
C042
Frequency arrival setting for accel
C043
Arrival frequency setting for decel
C044
PID deviation level setting
C052
PID FBV function high limit
C053
PID FBV function variable low limit
C071
Communication speed selection
• 04 4800 bps
• 05 9600 bps
• 06 19200 bps
C072
Node allocation
C074
Communication parity selection
• 00 No parity
• 01 Even parity
• 02 Odd parity
C075
Communication stop bit selection
C076
Communication error select
• 00 Trip (error code E60)
• 01 Decelerate to stop and trip (error code E60)
• 02 Disable
• 03 Free run stop (coasting)
• 04 Decelerate to a stop
C077
Communication error time-out
C078
Communication wait time
C081
O input span calibration
C082
OI input span calibration
C085
Thermistor input tuning
C086
[AM] terminal offset tuning
C091
Debug mode enable
• 00 Display
C101
Up/Down memory mode selection
• 00 Clear last frequency (return to default
frequency F001)
• 01 Keep last frequency adjusted by UP/DWN
Name / Description
• 01 No display
21
Default
Set
Value
Value
–FEF / –FU
Rated
current of
inverter
0.0
0.0
3.0
100.0
0.0
06 / 04
1.
00
1
02
0.00
0.
100.0
100.0
100.0
0.0
00
00

Advertisement

Table of Contents
loading

Table of Contents