Hitachi L300P Series Instruction Manual Supplement page 6

For inverters with model suffix of –lbrm or –hbrm
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

L300P Supplement
Function Mode
Display
Function name
code
F001
Output frequency
F002
Acceleration (1) time
F202
Acceleration (2) time
F003
Deceleration (1) time
F203
Deceleration (2) time
Keypad Run Key
F004
Routing
NOTE (1) : This value appears because lower limiter (A062, A262) is set to 15Hz.
Monitor or Data Range
(digital operator)
0.0, starting frequency to Maximum
frequency (Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000. -3600. (s)
0.01-99.99/100.0-999.9/1000. -3600. (s)
0.01-99.99/100.0-999.9/1000. -3600. (s)
00(forward)/01(reverse)
4
Explanation of functions
LBRM/
LFU/HFU
HBRM
Initial
Initial
Data
Data
15.00
NOTE (1)
60.00
30.00
60.00
30.00
90.00
30.00
90.00
30.00
00
0.00
00

Advertisement

Table of Contents
loading