L300P Supplement
Function mode
Code
Function name
b012
Electronic thermal level
Electronic thermal level
b212
nd
(2
motor)
Electronic thermal
b013
characteristic selection
Electronic thermal
b213
characteristic selection
nd
(2
motor)
Free electronic
b015
thermal frequency1
Free electronic thermal
b016
current1
Free electronic thermal
b017
frequency2
Free electronic thermal
b018
current2
Free electronic thermal
b019
frequency3
Free electronic thermal
b020
current3
Overload restriction
b021
selection
b022
Overload restriction level
Overload restriction
b023
limit constant
Overload restriction
b024
2 selection
b025
Overload restriction level2
Overload restriction
b026
constant2
Software
lock
b031
selection
b100
Free V/f frequency1
b101
Free V/f voltage1
b102
Free V/f frequency2
b103
Free V/f voltage 2
b104
Free V/f frequency3
b105
Free V/f voltage 3
b106
Free V/f frequency4
b107
Free V/f voltage 4
b108
Free V/f frequency5
b109
Free V/f voltage 5
b110
Free V/f frequency6
b111
Free V/f voltage 6
b112
Free V/f frequency7
b113
Free V/f voltage 7
0.2*constant current-1.20*constant current(A)
0.2*constant current-1.20*constant current(A)
00/(reduced characteristic)/01(constant characteristic)/
02(free setting)
00/(reduced characteristic)/01(constant torque characteristic)/
02(free setting)
00(invalid)/01(enabled on acceleration・constant speed)/
02(enabled on constant speed)
0.50* rated current-1.50* rated current(A)
00(invalid)/01(valid on acceleration・constant speed)/
02(valid on constant speed)
0.50*rated current-1.50*rated current(A)
00(impossible to change the data except this item on SFT terminal
ON)/
mode
01(impossible to change the data except setting frequency item on SFT
terminal is ON)/02(impossible to change the data except this item)/
03(impossible to change the data except setting frequency item)/
10(possible to change data on operating)
0.- Free V/f frequency2(Hz)
0.- Free V/f frequency3(Hz)
0.- Free V/f frequency4(Hz)
0.- Free V/f frequency5(Hz)
0.- Free V/f frequency6(Hz)
0.- Free V/f frequency7(Hz)
Setting range
0.-400.(Hz)
0.0-1000.(A)
0.-400.(Hz)
0.0-1000. (A)
0.-400.(Hz)
0.0-1000.(A)
0.10-30.00(s)
0.10-30.00(s)
0.-800.0(V)
0.-800.0(V)
0.-800.0(V)
0.-800.0(V)
0.-800.0(V)
0.-800.0(V)
0.-400.(Hz)
0.-800.0(V)
8
Explanation of functions
LBRM/HFBM
LFU/HFU
Initial Data
Initial data
Rated current
of inverter×
of inverter
1.20
Rated current
of inverter×
of inverter
1.20
00
01
0.
0.0
0.
0.0
0.
0.0
01
Rated Current
of inverter
of inverter
×1.20
10.00
01
Rated current
of inverter×
of inverter
1.20
1.00
01
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
Rated
current
Rated
current
01
01
0.
0.0
0.
0.0
0.
0.0
01
Rated
Current
×1.20
1.00
01
Rated
current
×1.20
1.00
01
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.