L300P Supplement
Function mode
Code
Function name
Intelligent input1a/b(NO/NC)
C011
selection
Intelligent input2a/b(NO/NC)
C012
selection
Intelligent input3a/b(NO/NC)
C013
selection
Intelligent input4a/b(NO/NC)
C014
selection
Intelligent input5a/b(NO/NC)
C015
selection
Input FWa/b(NO/NC)
C019
selection
C021
Intelligent output 11 setting
C022
Intelligent output 12 setting
C026
Alarm relay output setting
C027
FM selection
C028
AM selection
C029
AMI selection
C031
Intelligent output 11a/b
C032
Intelligent output 12a/b
C036
Alarm relay output a/b
Overload
advance
C040
signal output mode
C041
Overload notice level
Frequency arrival setting for
C042
accel.
Arrival frequency setting for
C043
decel.
C044
PID deviation setting level
Electorical thermal protection
C061
warning level setting
C070
Data command
Communicating
C071
speed
C072
Communication code
C073
Communication bit
C074
Communication parity
C075
Communication stop bit
C078
Communication waiting time
C081
O adjustment
C082
OI adjustment
C083
O2 adjustment
C085
Thermistor adjustment
C086
AM offset adjustment
C087
AMI adjustment
C088
AMI offset adjustment
NOTE (3) : See Page 1 (RMD : Output signal for RUN Command Source)
00(RUN:running)/01(FA1:Frequency arrivaltype1 signal)/
02(FA2:frequency arrival type2 signal)/
03(OL:Overload advance notice signal)/
04(OD:Output deviation for PID control)/
05(AL:Alarm signal)/06(FA3:Only setting frequency)/
08(IP:On instantaneous stop/09(UV:Under voltage/
11(RNT:RUN time over/
12(ONT:ON time over)/13(THM:thermal caution)/
27(RMD: RUN command source)
00(Output frequency)/01(Output current) /
03(Digital output frequency)/04(Output voltage)/
05(Output
electric
frequency)
00(Output frequency)/01(Output current)/04(Output voltage)/
05(Output
electric
frequency)
00(Output frequency)/01(Output current)/04(Output voltage)/
05(Output
electric
frequency)
notice
00(On accel. And decel, constant speed)/
01(Only constant speed)
02(operator)/03(RS485)/04(option1)/05(option2)
transmission
02(TEST)/03(2400bps)/04(4800bps)/05(9600bps)/06(19200bps)
00(no parity name)/01(even parity)/02(odd parity)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
Setting range
00(NO)/01(NC)
00(NO)/01(NC)
00(NO)/01(NC)
00(NO)/01(NC)
00(NO)/01(NC)
00(NO)/01(NC)
NOTE (3)
power)/06(thermal
load
power)/06(thermal
load
power)/06(Thermal
load
00(NO)/01(NC)
00(NO)/01(NC)
00(NO)/01(NC)
0.0-2.0*rated current(A)
0.00-99.99/100.0-400.0(Hz)
0.00-99.99/100.0-400.0(Hz)
0.0-100.0(%)
0.-100.(%)
1. -32.
7(7bit)/8(8bit)
1(bit)/2(bit)
0.-1000.(ms)
0.0 - 1000.
0.0 - 10.0(V)
0. - 255.
0. - 20.0(mA)
10
Explanation of functions
LBRM/HFBM
Initial Data
00
00
00
00
00
00
27
00
05
00
rate)/07(LAD
rate)/07(LAD
00
rate)/07(LAD
00
00
00
00
01
Inverter rated
current
0.00
0.00
3.0
80.
02
04
1.
7
00
1
0.
Setting on
forwarding
Setting on
forwarding
Setting on
forwarding
105.0
0.0
80
4.0
LFU/HFU
Initial data
00
00
01
00
00
00
01
00
05
00
00
00
00
00
01
01
Inverter
rated
current
0.00
0.00
3.0
80.
02
04
1.
7
00
1
0.
Setting on
forwarding
Setting on
forwarding
Setting on
forwarding
105.0
0.0
80
4.0

Advertisement