Chapter 6: Setting Regional Parameters; Advanced Scripting For Cadences, Call Progress Tones, And Ring Tones; Call Progress Tones - Linksys SPA922 Administrator's Manual

Business series
Hide thumbs Also See for SPA922:
Table of Contents

Advertisement

Advanced Scripting for Cadences, Call Progress Tones, and Ring Tones

• Example 1: Dial Tone
• 350@-19,440@-19;10(*/0/1+2)
• Number of Frequencies = 2
• Frequency 1 = 350 Hz at –19 dBm
• Frequency 2 = 440 Hz at –19 dBm
• Number of Cadence Sections = 1
• Cadence Section 1: Section Length = 10 s
• Number of Segments = 1
• Segment 1: On=forever, with Frequencies 1 and 2
• Total Tone Length = 10s
• Example 2: Stutter Tone
• 350@-19,440@-19;2(.1/.1/1+2);10(*/0/1+2)
• Number of Frequencies = 2
• Frequency 1 = 350 Hz at –19 dBm
• Frequency 2 = 440 Hz at –19 dBm
• Number of Cadence Sections = 2
• Cadence Section 1: Section Length = 2s
• Number of Segments = 1
• Segment 1: On=0.1s, Off=0.1s with Frequencies 1
and 2
• Cadence Section 2: Section Length = 10s
• Number of Segments = 1
• Segment 1: On=forever, with Frequencies 1 and 2
• Total Tone Length = 12s
Linksys SPA9x2 Phone Administration Guide
Setting Regional Parameters
65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spa932Spa942Spa962

Table of Contents