Checking the oil level in the oil reservoir of the maintenance unit
–
The oil level in oil reservoir 5 should not drop below the groove
marking.
–
If necessary, fill oil up to the groove marking.
–
For this completely shut off the compressed air by turning the knob
1 to the left.
–
To fill screw out the oil fill screw 3.
–
After filling with oil set an operating pressure of 6 bar by pulling up
the knob 1 and turning it to the right.
The set operating pressure can be seen on the pressure gauge 4.
Checking the oil flow of the oil mister
–
Under operating pressure a drop of oil should drip out of the tube
under viewing glass 5 after about 10 work cycles.
–
Regulate the strength of the thus created oil mist with the setting
screw 2.
1
2
3
4
5
17