C.6
Error 32:
„Thread position does not
come"
Error 33:
„Sewing motor does not
stop"
Error 34:
„Needle not up"
Error 35:
„Thread breakage"
Error 37:
„Thread only rest"
Error 41:
„No parts"
Error 42:
„Photocell not lighted"
Error 43:
„Photocell lighted too early"
Error 45 ... 48:
"I/O DAC, ULN, 485, RES"
Troubleshooting
During thread cutting, sewing motor did not
reach cutting position
After thread cutting, sewing motor does not
stop within error period
Needle not in upper rest position; when the
error message is issued, the control unit
attempts once more to move the needle to
the upper position
Thread monitor detects thread breakage
The photocell at the spool case is
illuminated, spool empty
Photocell FZ21 remains illuminated during
insertion
Photocell FZ21 does not detect end of
seam
Photocell FZ21 detects intermittent
reflection during insertion
Internal hardware error during data
transmission to adapter board 9020020
Input slower cutting speed and earlier
cutting position; replace sewing motor or
synchronizer
Input slower cutting speed and earlier
cutting position; replace sewing motor or
synchronizer
Check sewing motor and synchronizer;
check connection between 9020013 and
sewing motor; read condition of two upper
LEDs at 9020013: if no LED illuminates
when handwheel is rotated, check sewing
motor power supply; replace sewing motor
if required; if LEDs are OK, check
connection between 9020020 and sewing
motor; replace 9020020 if required
If spool is not empty, the photocell is
maladjusted (response too sensible); adjust
correctly
Adjust photocell sensibility; input test 21
Sewing distance too long; adjust photocell
sensibility; input test 21
Adjust photocell sensibility; input test 21
Replace 9020020