Hanna Instruments pH 211 Instruction Manual

Hanna Instruments pH 211 Instruction Manual

Microprocessor-based ph/mv/°c bench meters
Hide thumbs Also See for pH 211:

Advertisement

Instruction Manual
pH 210
pH 212
Microprocessor-based
pH/mV/°C
Bench Meters
w w w. h a n n a i n s t . c o m
1
pH 211
pH 213

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the pH 211 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hanna Instruments pH 211

  • Page 1 Instruction Manual pH 210 pH 211 pH 212 pH 213 Microprocessor-based pH/mV/°C Bench Meters w w w. h a n n a i n s t . c o m...
  • Page 2: Table Of Contents

    BUFFER TEMPERATURE DEPENDENCE........19 ELECTRODE CONDITIONING & MAINTENANCE ....... 20 TROUBLESHOOTING GUIDE ............23 TEMPERATURE CORRELATION FOR pH SENSITIVE GLASS ....24 Hanna Instruments reserves the right to modify the design, ACCESSORIES ................25 construction and appearance of its products without advance notice.
  • Page 3: Functional Description Ph 210 And Ph 211

    FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION p p p p p H 210 AND H 210 AND H 210 AND p p p p p H 211 H 210 AND H 211 H 211 H 211 FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION H 210 AND H 211 p p p p p H H H H H 210 AND...
  • Page 4 p p p p p H H H H H 2 1 2 A N D 2 1 2 A N D 2 1 2 A N D 2 1 2 A N D p p p p p H H H H H 2 1 3 2 1 3 2 1 3 2 1 3...
  • Page 5: Operational Guide

    • The pH is displayed on the primary LCD and the temperature on OPERATIONAL GUIDE OPERATIONAL GUIDE OPERATIONAL GUIDE OPERATIONAL GUIDE OPERATIONAL GUIDE the secondary LCD. POWER CONNECTION POWER CONNECTION POWER CONNECTION POWER CONNECTION POWER CONNECTION Plug the 12 VDC adapter into the power supply socket. Notes: •...
  • Page 6: Ph Calibration

    • The instrument displays the mV reading on the primary LCD and p p p p p H CALIBRATION H CALIBRATION H CALIBRATION H CALIBRATION H CALIBRATION the temperature on the secondary LCD. Calibrate the instrument often, especially if high accuracy is required. The instrument should be recalibrated: •...
  • Page 7 • When the reading is stable and close to the selected buffer, • Press RANGE to display the tem- “READY” tag will appear and “CFM” tag will blink. perature reading on the LCD during calibration (pH 211, pH 212, pH •...
  • Page 8: Temperature Calibration (For Technical Personnel Only)

    • Immerse the temperature probe in the second vessel as near as TEMPERATURE CALIBRATION TEMPERATURE CALIBRATION TEMPERATURE CALIBRATION TEMPERATURE CALIBRATION TEMPERATURE CALIBRATION possible to the reference thermometer. Allow a few seconds for the ( ( ( ( ( f o r t e c h n i c a l p e r s o n n e l o n l y f o r t e c h n i c a l p e r s o n n e l o n l y f o r t e c h n i c a l p e r s o n n e l o n l y f o r t e c h n i c a l p e r s o n n e l o n l y ) ) ) ) )
  • Page 9: Mv Calibration (Ph 213 Only) (For Technical Personnel Only)

    PC may not be possible. • With the instrument off, press and hold down the MR&CFM • If you are not using Hanna Instruments HI 92000 keys, then power on the instrument. The “CAL” tag will appear software, please see the following instructions.
  • Page 10 SENDING COMMANDS FROM PC SENDING COMMANDS FROM PC SENDING COMMANDS FROM PC SENDING COMMANDS FROM PC SENDING COMMANDS FROM PC p p p p p H BUFFER TEMPERATURE H BUFFER TEMPERATURE H BUFFER TEMPERATURE H BUFFER TEMPERATURE H BUFFER TEMPERATURE D E P E N D E N C E D E P E N D E N C E D E P E N D E N C E...
  • Page 11: Electrode Conditioning & Maintenance

    For refillable electrodes: For refillable electrodes: For refillable electrodes: For refillable electrodes: For refillable electrodes: ELECTRODE CONDITIONING & ELECTRODE CONDITIONING & ELECTRODE CONDITIONING & ELECTRODE CONDITIONING & ELECTRODE CONDITIONING & M A I N T E N A N C E M A I N T E N A N C E M A I N T E N A N C E M A I N T E N A N C E...
  • Page 12: Troubleshooting Guide

    CLEANING PROCEDURE CLEANING PROCEDURE CLEANING PROCEDURE CLEANING PROCEDURE CLEANING PROCEDURE T R O U B L E S H O O T I N G G U I D E T R O U B L E S H O O T I N G G U I D E T R O U B L E S H O O T I N G G U I D E T R O U B L E S H O O T I N G G U I D E T R O U B L E S H O O T I N G G U I D E...
  • Page 13: Temperature Correlation For Ph Sensitive Glass

    TEMPERATURE CORRELATION TEMPERATURE CORRELATION TEMPERATURE CORRELATION TEMPERATURE CORRELATION TEMPERATURE CORRELATION A C C E S S O R I E S A C C E S S O R I E S A C C E S S O R I E S A C C E S S O R I E S A C C E S S O R I E S FOR p p p p p H SENSITIVE GLASS...
  • Page 14 HI 1330B ORP PRETREATMENT SOLUTIONS HI 7091L Reducing Pretreatment Solution, 460 mL bottle Glass-body, semimicro, single junction, refillable, combination pH electrode. Use: laboratory, vials. HI 7092L Oxidizing Pretreatment Solution, 460 mL bottle pH ELECTRODES 5mm DIA 0.2" 0.2" All electrodes part numbers ending with B are supplied with BNC HI 1330 connector and 1 m (3.3') cable, as shown below : 120 mm...
  • Page 15 FC 100B HI 1413B Plastic-body (Kynar ), double junction, refillable, combination pH Glass-body, single junction, flat tip, Viscolene, non-refillable, combination ® electrode. Use: general purpose for food industry. pH electrode. Use: surface measurement. 12 mm 12 mm 0.5" 0.5" FC 100 HI 1413 120 mm 110 mm...
  • Page 16 EXTENSION CABLE FOR SCREW-TYPE ELECTRODES RECOMMENDATIONS FOR USERS (SCREW TO BNC ADAPTER) Before using these products, make sure they are entirely suitable for HI 7855/1 Extension cable 1 m (3.3') long the environment in which they are used. HI 7855/3 Extension cable 3 m (9.9') long Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment, requiring the...
  • Page 17 SALES AND TECHNICAL SERVICE CONTACTS Australia: Tel. (03) 9769.0666 • Fax (03) 9769.0699 China: Tel. (10) 88570068 • Fax (10) 88570060 Egypt: Tel. & Fax (02) 2758.683 Germany: Tel. (07851) 9129-0 • Fax (07851) 9129-99 Greece: Tel. (210) 823.5192 • Fax (210) 884.0210 Indonesia: Tel.

This manual is also suitable for:

Ph 212Ph 210Ph 213

Table of Contents

Save PDF