Lenovo ThinkStation D20 Hardware Maintenance Manual page 75

Hardware maintenance manual
Hide thumbs Also See for ThinkStation D20:
Table of Contents

Advertisement

Diagnostic Error Code
080-197-XXX Game Port interface test warning
080-198-XXX Game Port interface test aborted
080-199-XXX Game Port interface test failed, cause
unknown
086-000-XXX Mouse Port interface Test Passed
086-001-XXX Mouse Port interface Presence
086-032-XXX Mouse Port interface Device controller
failure
086-035-XXX Mouse Port interface Reset
086-040-XXX Mouse Port interface IRQ failure
086-195-XXX Mouse Port interface Test aborted by user
086-196-XXX Mouse Port interface test halt, error
threshold exceeded
086-197-XXX Mouse Port interface test warning
086-198-XXX Mouse Port interface test aborted
FRU/Action
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 41
2. Flash the system and re-test. See "Flash update
procedures" on page 251
3. Go to "Undetermined problems" on page 75
1. See "Undetermined problems" on page 75
2. Flash the system and re-test. See "Flash update
procedures" on page 251
3. Replace component under function test
No action
1. Mouse
2. System board
1. Mouse
2. System board
1. Mouse
2. System board
1. Run Setup
2. Mouse
3. System board
Information only Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 41
2. Flash the system and re-test. See "Flash update
procedures" on page 251
3. Go to "Undetermined problems" on page 75
Chapter 9
.
Symptom-to-FRU Index
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents