Carrier 38EYA Installation And Start-Up Instructions Manual page 5

12 seer split-system heat pump with puron
Hide thumbs Also See for 38EYA:
Table of Contents

Advertisement

ACCESSORY
Crankcase Heater
Evaporator Freeze Thermostat
Compressor Start Assist—Capacitor and Relay
Puron® Low-Ambient Pressure Switch
Wind Baffle
Support Feet
Hard Shutoff TXV
Liquid-Line Solenoid Valve for Heating
* For tubing line sets between 50 and 175 ft, or when vertical difference is greater than 20 ft, refer to Application Guideline and Service Manual — Residential Split-System
Air Conditioners and Heat Pumps Using Puron®.
† Required for all applications.
wrench an additional 1/12 turn (15 ft-lb). DO NOT OVER-
TIGHTEN.
REFRIGERANT TUBING AND FILTER DRIER
Installation of filter drier in liquid line is required.
Connect vapor tubing to fittings on outdoor unit vapor service
valves. Connect liquid tube to filter drier. (See Table 1 and Fig. 8.)
Use refrigerant grade tubing. Connect other end of filter drier to
adapter tube on liquid service valve.
SWEAT CONNECTION
To avoid valve damage while brazing, service valves must be
wrapped in a heat-sink material such as a wet cloth.
Wrap service valves and filter drier with a wet cloth or heat-
sinking material. Braze connections using either silver bearing or
non-silver bearing brazing material. Do not use soft solder
(materials which melt below 800°F.) Consult local code require-
ments.
LEAK CHECKING
Leak test all joints in indoor, outdoor, and refrigerant tubing.
EVACUATE REFRIGERANT TUBING AND INDOOR COIL
Never use the system compressor as a vacuum pump.
Refrigerant tubes and indoor coil should be evacuated using the
recommended deep vacuum method of 500 microns. The alternate
triple evacuation method may be used if the procedure outlined
below is followed.
IMPORTANT: Never open system under vacuum to atmosphere
without first breaking it open with nitrogen.
Deep Vacuum Method
The deep vacuum method requires a vacuum pump capable of
pulling a vacuum of 500 microns and a vacuum gage capable of
accurately measuring this vacuum depth. The deep vacuum
method is the most positive way of assuring a system is free of air
and liquid water. (See Fig. 9.)
Triple Evacuation Method
The triple evacuation method should only be used when vacuum
pump is only capable of pumping down to 28 in. of mercury
vacuum and system does not contain any liquid water. Refer to
Fig. 10 and proceed as follows:
Table 2—Accessory Usage
REQUIRED FOR LOW-AMBIENT
APPLICATIONS
(BELOW 55°F)
Yes
Yes
Yes
Yes
See Low-Ambient Instructions
Recommended
Yes†
No
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
BREAK VACUUM WITH DRY NITROGEN
BREAK VACUUM WITH DRY NITROGEN
5
REQUIRED FOR LONG-LINE
APPLICATIONS*
(OVER 50 FT)
See Long-Line
Application Guideline
0
1
2
3
4
MINUTES
Fig. 9—Deep Vacuum Graph
EVACUATE
WAIT
EVACUATE
WAIT
EVACUATE
CHECK FOR TIGHT, DRY SYSTEM
(IF IT HOLDS DEEP VACUUM)
CHARGE SYSTEM
Fig. 10—Triple Evacuation Method
Yes
No
Yes
No
No
No
Yes†
LEAK IN
SYSTEM
VACUUM TIGHT
TOO WET
TIGHT
DRY SYSTEM
5
6
7
A95424
A95424
A95425

Hide quick links:

Advertisement

Table of Contents
loading