Electrolux CH600-900 User Manual page 44

Electrolux cooker hood user manual
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 33
Electrical connection for UK
only
WARNING: DOUBLE INSULATED
DO NOT EARTH
Electrical Requirements
Any permanent electrical installation must comply
with the latest I.E.E. Regulations and local Elec-
tricity Board regulations. For your own safety this
should be undertaken by a qualified electrician e.g.
your local Electricity Board, or a contractor who is
on the roll of the National Inspection Council for
Electrical Installation Contracting (NICEIC) or a
suitably competent person.
Electrical Connection
Before connecting to the mains supply ensure that
the mains voltage corresponds to the voltage on the
rating plate inside the cooker hood.
This appliance is fitted with a 2 core mains cable
and must be permanently connected to the electric-
ity supply via a double-pole switch having 3mm
minimum contact gap on each pole. A Switched
Fuse Connection Unit to BS1363 Part 4, fitted with
a 5 Amp time delay fuse, is a recommended mains
supply connection accessory to ensure compliance
with the Safety Requirements applicable to fixed
wiring instructions.
This appliance conforms to BS 800: 1988 and EEC
Directive No. 78 308 regarding suppression of
radio and television interference.
Safety warnings for the electrician
The following is valid in Ireland only:
- the wire which is coloured blue must be
connected to the terminal which is marked with
the letter N,
- the wire which is coloured brown must be
connected to the terminal which is marked with
the letter L.
44

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents