LCD Lift Codes
Listed below are codes that the lift controller
outputs during lift operation. The codes will be
displayed on an LCD screen located on the lift
control board inside the pump module.
Non-Flashing Numbers
01 – Platform stowed
57 – Outer barrier is not up and latched and
02 – Platform unfolding
ground detect switch did not deactivate
03 – Platform unfolding paused
(Century and Vista only)
04 – Platform at floor level
58 – Outer barrier is not up and latched and the
05 – Platform beginning to lower
platform is 3
above the ground
"
06 – Platform lowering (threshold cannot be
59 – Outer barrier is not up after pausing
occupied from this point down)
platform travel
07 – Outer barrier moving to horizontal
60 – The kickout gas springs are worn, replace
position
before using
08 – Platform at ground level
75 – Low voltage detected; must turn off power
09 – Outer barrier moving to vertical position
switch to reset LCD
10 – Platform raising
77 – Vehicle secure interlock has not been
11 – Platform raising paused at floor
activated
12 – Platform folding (limited pressure)
90 – Position will be set if you keep holding the
13 – Platform folding (full pressure)
button until it beeps
14 – Timed fold (cinching lift tite) or (anti-rattle
91 – Position is out of a predetermined
state)
acceptable range of floor position
15 – Platform folding stopped
92 – Bridge switch is not made, needs adjusting
16 – Paused fold
93 – Inner rollstop occupied switch is not made,
17 – Platform between ground and 3
above
position needs to be moved or switch
"
ground
should be adjusted
18 – Platform above 3
94 – Outer barrier is not made, fix and try again
"
19 – Outer barrier moving to horizontal
95 – Outer barrier latch is not made (check for
postion
jumper on Century and Vista lifts, check
20 – The doors are not fully opened (only
latch on Millennium lifts)
applicable when door operators are
99 – Controller program is not valid; replace
installed)
controller
21 – The doors are opening (only applicable
when door operators are installed)
22 – The doors are closing (only applicable
Flashing Numbers
when door operators are installed)
28 – Illegal function/not defined
Flashing 65 – Unfold button is pressed
29 – Interlock fault not recognized (or has
Flashing 66 – Fold button is pressed
been cleared but a motion button is still
Flashing 67 – Down button is pressed
pressed)
Flashing 68 – Up button is pressed
30 – Platform location unknown
Flashing 69 – Bridge switch is activated
31 – Platform location transition state;
Flashing 70 – Outer barrier latch switch is
attempting to locate position
activated
35 – Two or more motion buttons are being
Flashing 71 – Ground detect switch is activated
pressed
Flashing 72 – Outer barrier up switch is activated
36 – The retention belt cannot be buckled
Flashing 73 – Inner rollstop up switch is activated
while trying to fold or unfold
Flashing 74 – Inner rollstop occupied switch is
37 – Motion button being pressed is not a
activated
valid motion
Flashing 76 – Outboard barrier occupied switch
50 – Outer barrier is not up above inboard
is activated
barrier locked position
Flashing 78 – Threshold tape switch "A" is
51 – Threshold is occupied when platform is
activated
1
or more below floor level
Flashing 79 – Threshold tape switch "B" is
"
activated
52 – Inner rollstop is not up and locked below
inner rollstop locked position
Flashing 80 – Position set button is pressed
53 – Inner rollstop occupied sensor is not
Flashing 81 – Single function UP / FOLD /
activated between floor and inner rollstop
CLOSE button is pressed
up position
Flashing 82 – Single function OPEN / UNFOLD /
54 – Outer barrier is occupied before it is up
DOWN button is pressed
55 – Outer barrier is not latched when above
Flashing 87 – CLOSE button is pressed
the inner rollstop locked position
Flashing 88 – OPEN button is pressed
(Millennium only)
Flashing 89 – Door full open switch is activated
56 – Outer barrier is not up and latched and
(or jumper is installed on control
bridge switch did not deactivate
board)
Decals and Antiskid
Decals
32201
PLATFORM FOLD
RELIEF VALVE
ADJUSTMENT
Platform Fold
Relief Valve:
See service
manual for
adjustment
procedure.
32410
32201
25580
30787
C A U T I O N
Improper handling
and/or servicing
procedures may
result in
electrostatic
discharge (ESD)!
ESD may result in
electronic module
damage.
30787
18229
MADE IN
AMERICA
Quality inspected
By:
18229
25652
25652
Page 41