Alarm connector

Pin
1
2
3
4
Max. wire diameter AWG 22-28 for both stranded and solid
Default relay position n.o. (normally open), no alarm
Alarm output relay switching capability: Max voltage 30VAC or
+40VDC. Max 0.5 A continuous, 10VA.
Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with
22kΩ pull-up to +3.3V
Alarm in: configurable as active low or active high
Max. 42V allowed between camera ground and each of the relay pins.

Lens mounting

The camera accepts CS-mount lenses. C-mount lenses can be mounted
using the lens adapter ring. DC-iris lenses are recommended for the best
picture performance. The camera automatically detects the type of lens
used and optimizes performance accordingly. A spare male lens connector
is provided.
Caution
To avoid damaging the CCD sensor when using a C-mount lens,
make sure the supplied lens adapter ring is mounted onto the
camera before mounting the lens.
Lenses weighing more than 0.5 kg (1. 1 lbs) must be separately
supported.
Bosch Security Systems | 2004-01 | V1.0
Alarm socket
Alarm in Ground
Alarm in
Relay out contact 1
Relay out contact 2
Alarm
Pin 1
Pin 4
EN | 9