RME Audio Hammerfall DIGI 9636 User Manual page 12

Pci busmaster digital i/o card 2 + 16 channels stereo / adat interface 24 bit / 96 khz digital audio adat sync in
Table of Contents

Advertisement

MME
Check Input verifies the current input signal against the settings in the record program. When
de-activated a record will always be allowed, even with non-valid input signals.
Monitoring activates the automatic pass-through of the input signal when in record mode. Both
settings are valid for MME only.
AEB
After activating ADAT1 Int. the optical input ADAT1 will be routed to the internal input (CD In).
Then the 4- or 8-channel signal of an AEB-I can be received. The optical input can no longer be
used with an ADAT signal, but can still be used as SPDIF input. For this to work select 'ADAT1'
under 'SPDIF In'.
Buffer Size
The setting Buffer Size determines the latency between incoming and outgoing ASIO* data, as
well as affecting system stability (see chapter 13). Under Windows MME this setting determines
the DMA buffer size (see chapter 8.6).
SPDIF In
Defines the input for the SPDIF signal.
'Coaxial' relates to the white phono
plug, 'Internal' to the jumper CD In
(ST3), 'ADAT1' to the optical input
ADAT1.
SPDIF Out
The SPDIF output signal is constantly
available at the internal jumper Sync
Out (ST4) and the red phono plug.
After selecting 'ADAT1' it is also routed
to the optical output ADAT1. For
further
details
about
'Professional', 'Emphasis' and 'Non-
Audio', please refer to chapter 12.
Clock Mode
The card can be configured to use the
following clock sources: external input
signal
(AutoSync),
(Master), or external word clock signal
(Wordclock).
Pref. Sync Ref.
Used to pre-select the desired clock source. If the selected source isn't available the card will
change to the next available one. The currently used clock source and sample rate is displayed
in the SyncRef display.
Status Displays
The status displays at the bottom of the dialog box give various useful information, like
synchronicity of the inputs, sample rate at the SPDIF input, detected Time Code at the ADAT
Sync In, and input and frequency of the current sync source.
* Under W2k/XP also GSIF data
Note: Screenshot shows DIGI9652 settings dialog
the
settings
internal
clock
User's Guide DIGI9636 © RME