18. Remote Start in Valet Mode. Determines if
the remote start feature will operate when the
alarm is set for valet mode.
19. Program RPM. When the remote start is
connected, pressing transmitter button I
"learns" the RPM. Pressing button 2 or 3 sets
the engine mode for gas or diesel.
20. Automatic Starting. Selects between off, low
temperature starting, and low voltage starting.
21. FM Transmitter Module. Pressing button 1
learns the add-on FM module ID so the FM
transmitter can operate the system. Pressing
button 2 learns the FM transmitter. After pressing
button 2 on the AM remote, press transmitter
button 1 on each FM remote (max 2).
Complete Default Reset
Following this procedure will set all User and
Installer Programming Parameters to factory
default settings.
1. Enter System Programming.
2. Press Transmitter Button 3.
• The siren will chirp 6 times indicating the
reset signal was received.
• All Installer and User Programming options
are now set to factory default settings.
3. Turn ignition off.
Test System and Adjust Shock Sensor
Arm and disarm system, checking that the siren
chirps and parking lights are functioning
normally. Make sure that the programmed
features are performing correctly, ie.: ignition
locks, passive arming, passive locks, etc.
Test the doors and hood/trunk inputs (make
sure all doors trigger the system, not just the
drivers door).
Adjust the shock sensor. (see Real-time Sensor
Adjustment Mode)
Arm the system and try starting the vehicle, it
should not start.
Arm the system and disarm it with the ignition
and valet switch.
If programmed to passively arm make sure that
the system arms properly.
Check the range of the remote transmitters.
Tie up wire harness, and replace any under dash
panels.
Make sure the customer has physical knowledge
of the location of the valet/override switch.
Real-time Sensor Adjustment Mode
This mode allows active testing of the shock
sensor and optional sensor input making
adjustments without arming the alarm.
To enter Sensor Adjustment mode:
1. Turn the ignition on.
2. Press the Shift Button (Button 5) 3 times,
then Button 3.
• The siren will chirp 4 times, indicating that
the sensor is ready to be tested.
3. Test the sensitivity. The siren will chirp a
number of times each time a sensor is
triggered.
• One chirp indicates the shock sensor.
• Two chirps indicates the warn away.
• Three chirps indicates the optional sensor.
4. To make shock senosr adjustments:
• Turn the adjustment screw on the sensor
clockwise to increase the sensitivity.
• Turn the adjustment screw on the sensor
counter clockwise to decrease the
sensitivity.
5. Turn off the ignition when the desired
sensitivity level is reached.