Patton 3088A Series User Manual

Onsite 3088a series g.shdsl.bis cpe with fixed serial interface
Table of Contents

Advertisement

For Quick
Start Installation
OnSite Model 3088A Series
G.SHDSL.bis CPE with fixed

serial interface

User Manual
Important
This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial
or residential environment.
REGULATORY MODEL NUMBER: 03340D4-001
Sales Office:
+1 (301) 975-1000
Technical Support:
+1 (301) 975-1007
E-mail:
support@patton.com
WWW:
www.patton.com
Part Number: 07M3088A, Rev. A
Revised: March 30, 2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3088A Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Patton 3088A Series

  • Page 1: Serial Interface

    For Quick Start Installation OnSite Model 3088A Series G.SHDSL.bis CPE with fixed serial interface User Manual Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial or residential environment.
  • Page 2 Patton Electronics Company, Inc. 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA Tel: +1 (301) 975-1000 Fax: +1 (301) 869-9293 Support: +1 (301) 975-1007 Web: www.patton.com E-mail: support@patton.com Trademark Statement The term OnSite is a trademark of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.
  • Page 3: Summary Table Of Contents

    Summary Table of Contents General information ............................14 2 Configuration..............................18 OnSite installation ............................34 Operation ..............................41 Remote console operation ..........................45 Software Upgrade ............................49 Reset configuration to factory defaults......................51 Contacting Patton for assistance ........................53 Compliance information ..........................
  • Page 4: Table Of Contents

    Table of Contents Summary Table of Contents ........................... 3 Table of Contents ............................4 List of Figures ..............................8 List of Tables ..............................9 About this guide ............................10 Audience................................10 Structure................................10 Precautions ................................11 Safety when working with electricity .......................12 ..................................13 General observations...
  • Page 5 Model 3088A Series User Manual Table of Contents Example Command Line Interface Session ....................31 OnSite Plug ‘n’ Play ............................33 OnSite installation ............................34 Installation ................................35 Connecting the twisted pair interface ......................35 Connecting the Model 3088A serial interface ....................36 Connecting the Model 3088A to a “DCE” or “DTE” device ..............36...
  • Page 6 Model 3088A Series User Manual Table of Contents Patton support headquarters in the USA ......................54 Alternate Patton support for Europe, Middle East, and Africa (EMEA) ............54 Warranty Service and Returned Merchandise Authorizations (RMAs)..............54 Warranty coverage ............................54 Out-of-warranty service ..........................55 Returns for credit ............................55...
  • Page 7 Model 3088A Series User Manual Table of Contents Factory default values for software-configurable parameters...................64 Factory replacement parts and accessories ....................66 Factory replacement parts and accessories ......................67 Interface pinouts ............................68 Line port ................................69 RS-232 interface..............................69 V.35 interface................................70 E1 interface ................................70...
  • Page 8: List Of Figures

    List of Figures OnSite 3088A ................15 Power connection barrel receptacle 5 VDC diagram .
  • Page 9: List Of Tables

    List of Tables General conventions ..............13 OnSite configurable parameters .
  • Page 10: About This Guide

    About this guide This guide describes installing and operating the Patton Electronics Model 3088A G.SHDSL OnSite™ CPE. Audience This guide is intended for the following users: • Operators • Installers • Maintenance technicians Structure This guide contains the following chapters and appendices: •...
  • Page 11: Precautions

    Model 3088A Series User Manual Precautions Notes, cautions, and warnings, which have the following meanings, are used throughout this guide to help you become aware of potential problems. Warnings are intended to prevent safety hazards that could result in per- sonal injury.
  • Page 12: Safety When Working With Electricity

    Model 3088A Series User Manual Safety when working with electricity • Do not open the device when the power cord is connected. For systems without a power switch and without an external power adapter, line volt- ages are present within the device when the power cord is connected.
  • Page 13: General Observations

    Model 3088A Series User Manual Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent CAUTION failures. Do the following to prevent ESD: •...
  • Page 14: General Information

    Chapter 1 General information Chapter contents OnSite 3088A overview............................15 Serial interface types ..............................15 Features .................................15 Power input connector ............................16 External AC universal power supply ........................16 External 48 VDC power supply ........................17...
  • Page 15: Onsite 3088A Overview

    Model 3088A Series User Manual 1 • General information OnSite 3088A overview The Patton Electronics Model 3088A G.SHDSL OnSite provides high speed 2-wire connectivity to ISPs, PTTs, and enterprise environments using Symmetrical High-data-rate Digital Subscriber Line (G.SHDSL) technology. As a symmetric DSL CPE, OnSite DSL offers the same data rates in both directions over a single pair of regular twisted pair lines using TC-PAM modulation.
  • Page 16: Power Input Connector

    Model 3088A Series User Manual 1 • General information • 10/100 Ethernet port for management and configuration • Built-in testing and diagnostics • OnSite Plug ‘n’ Play for easy installations • Interoperable with other Patton G.SHDSL modems • Configurable as remote (CP) units •...
  • Page 17: External 48 Vdc Power Supply

    Model 3088A Series User Manual 1 • General information External 48 VDC power supply The external DC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. The interconnecting cables...
  • Page 18: Configuration

    Chapter 2 Configuration Chapter contents Introduction ................................19 Software (CLI) configuration ..........................19 Hardware (DIP-switch) configuration ......................19 Configuring the DIP switches .........................21 System reset mode ............................22 DIP switch settings ............................22 DIP switch settings ............................23 S4-2 through S4-8: Data Rate ........................24 DCE/DTE operation ..........................26 Ethernet Management Port ..........................27...
  • Page 19: Introduction

    Model 3088A Series User Manual 2 • Configuration Introduction You can configure the OnSite (see figure 3) in one of two ways: • Software configuration using command line interface (CLI) via the console port • Hardware configuration via DIP switches Figure 3.
  • Page 20: Onsite Configurable Parameters

    Model 3088A Series User Manual 2 • Configuration Table 2 lists the Model 3088A’s configurable parameters. Table 2. OnSite configurable parameters Parameter Description Possible Values Password The password used to login to the console. 1-10 characters Circuit ID The circuit ID used to identify the unit.
  • Page 21: Configuring The Dip Switches

    Model 3088A Series User Manual 2 • Configuration Table 2. OnSite configurable parameters (Continued) Parameter Description Possible Values Pass Alarms When enabled, the OnSite passes alarms detected on one E1 net- Enabled or Disabled (Model /K) work over the DSL link to the remote E1 network.
  • Page 22: System Reset Mode

    Model 3088A Series User Manual 2 • Configuration The three sets of DIP switches are externally accessible from the underside of the Model 3088A (see figure 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8...
  • Page 23: Dip Switch Settings

    Model 3088A Series User Manual 2 • Configuration DIP switch settings The following tables provide an overview of the OnSite DIP switch functions. Table 3. Model 3088A Series - S1 DIP-Switch Functions (Configuration) Function Function Position (/A, /CA, /D models)
  • Page 24: S4-2 Through S4-8: Data Rate

    Model 3088A Series User Manual 2 • Configuration S4-2 through S4-8: Data Rate Switches S4-2 through S4-8 define both the DSL line rate and the serial data rate. Note For 3088A/K models, only columns S4-4 through S4-8 apply in this table.
  • Page 25 Model 3088A Series User Manual 2 • Configuration Table 5. S4-2 through S4-8 Data Rate DIP switch settings (Continued) S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate (kbps) 2240 2304 2368 2432 2496 2560 2624 2688 2752 2816 2880...
  • Page 26: Dce/Dte Operation

    Model 3088A Series User Manual 2 • Configuration Table 5. S4-2 through S4-8 Data Rate DIP switch settings (Continued) S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate (kbps) 4672 4736 4800 4864 4928 4992 5056 5120 5184 5248 5312...
  • Page 27: Ethernet Management Port

    Model 3088A Series User Manual 2 • Configuration Ethernet Management Port The 3088A offers a 10/100 Ethernet port for configuration and management via Telnet sessions. Because the Ethernet port is configured as MDI, a crossover Ethernet cable is required when connecting directly from a local PC or laptop.
  • Page 28 Model 3088A Series User Manual 2 • Configuration • Annex: Either G.991.2 Annex A or Annex B. The following status information is available through the command line interface: • Configuration Mode: Whether the 3088A is configured by DIP switches or software.
  • Page 29: Help Commands

    Model 3088A Series User Manual 2 • Configuration Bursty Errored Seconds Degraded Minutes Help Commands The following commands are provided to help the user find the correct command: • help: Lists all the commands that the console recognizes. • system help: Lists all the commands that start with system that the console recognizes.
  • Page 30: Dsl Configuration Commands

    Model 3088A Series User Manual 2 • Configuration DSL Configuration Commands The following commands are used to configure the DSL: • dsl set timeslots <1–32 (e1) | 89 (v.35, x.21) | 4 (rs-232)>: Sets the number of timeslots. For E1 NTUs, the number of E1 timeslots is set simultaneously.
  • Page 31: Remote Console

    Model 3088A Series User Manual 2 • Configuration Remote Console Provided that there is a DSL link to a second 3088A, a user may login to the first 3088A’s console and enter the remote console command to access the second 3088A’s console. Using this remote console feature, the user can configure and query the status of the second 3088A from a remote location.
  • Page 32 Model 3088A Series User Manual 2 • Configuration password ... Set the login password. circuitid ... Change the circuit ID clockmode ... Change the clocking mode ipaddress ... Set the IP address of the console port 3088A> system set circuitid "3088A/K Circuit ID"...
  • Page 33: Onsite Plug 'N' Play

    Model 3088A Series User Manual 2 • Configuration OnSite Plug ‘n’ Play The OnSite Plug ‘n’ Play feature allows ISPs, carriers and PTTs to quickly upgrade the link speed for a cus- tomer without requiring a visit to re-configure the Customer Premise (CP) Model 3088A. This feature also allows service providers to set up all of the configurations at the Central Office (via the ForeFront AIS system) before installing the stand alone units, saving time spent configuring or re-configuring DIP switches.
  • Page 34: Onsite Installation

    Chapter 3 OnSite installation Chapter contents Installation ................................35 Connecting the twisted pair interface ......................35 Connecting the Model 3088A serial interface ....................36 Connecting the Model 3088A to a “DCE” or “DTE” device ..............36 Connecting the Model 3088A/K serial interface .....................37 Connecting the Model 3088A/K to an E1 Network ..................37 Connect twisted pair (120 ohm) to E1 network ....................37...
  • Page 35: Installation

    Model 3088A Series User Manual 3 • OnSite installation Installation Once the Model 3088A is properly configured, it is ready to connect to the twisted pair interface, to the serial port, and to the power source. This section tells you how to make these connections.
  • Page 36: Connecting The Model 3088A Serial Interface

    Model 3088A Series User Manual 3 • OnSite installation Connecting the Model 3088A serial interface This section describes how to connect the serial ports to your serial equipment. The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt-...
  • Page 37: Connecting The Model 3088A/K Serial Interface

    Model 3088A Series User Manual 3 • OnSite installation Connecting the Model 3088A/K serial interface The Model 3088A/K provides an E1 (G.703/G.704) interface on dual BNC connectors and an RJ-48C receptacle. The interconnecting cables shall be acceptable for external use...
  • Page 38: Connecting Dual Coaxial Cable (75 Ohm) To E1 Network

    Model 3088A Series User Manual 3 • OnSite installation Connecting dual coaxial cable (75 ohm) to E1 network The Model 3088A/K is also equipped with dual female BNCs (TX and RX) for connection to a 75 ohm dual coax E1 network interface. If your E1 network terminates via dual coaxial cable, use...
  • Page 39: Connecting Power

    Model 3088A Series User Manual 3 • OnSite installation Connecting power External AC universal power supply 1. Connect the power cord from the AC socket to the IEC-320 power entry connector on the universal input power supply. The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator.
  • Page 40: Dc Power

    Model 3088A Series User Manual 3 • OnSite installation DC Power The 36-60 VDC DC to DC adapter is supplied with the DC version of the Model 3088A. The black and red leads plug into a DC source (nominal 48VDC) and the barrel power connector plugs into the barrel power supply jack on the 3088A.
  • Page 41: Operation

    Chapter 4 Operation Chapter contents Introduction ................................42 Power-up ................................42 LED status monitors ............................42 Power (Green) ............................42 DSL (Green) .............................42 Link (Green) (Model /K) ..........................42 Terminal (Green) ............................43 TM/ER (Yellow) ............................43 LOS (Red) [Model /K] ..........................43 Link (Green) .............................43 Activity (Green) ............................43 Test modes ..............................43...
  • Page 42: Introduction

    Model 3088A Series User Manual 4 • Operation Introduction Once the Model 3088A is properly configured and installed, it should operate transparently. The following sections describe power-up, reading the LED status monitors, and using the built-in loopback test modes. Power-up To apply power to the Model 3088A, first be sure that you have read section “Power input connector”...
  • Page 43: Terminal (Green)

    Model 3088A Series User Manual 4 • Operation Terminal (Green) The Terminal LED glows solid under the following circumstances: • 3088A/CA with V.35 interface and 3088A/A with RS-232 interface: if the serial interface has asserted • 3088A/D with the X.21 interface Configured as DCE: Indicates that the “Control”...
  • Page 44: Patterns

    Model 3088A Series User Manual 4 • Operation Note Local loopback causes bit errors on the remote end if the link is up. 511 Pattern Framer Framer 511 Pattern Generator Line Generator 511 BER 511 BER Meter Meter Figure 14. Local Analog Loopback diagram The data received from the serial interface is looped back before going out on the DSL line.
  • Page 45: Remote Console Operation

    Chapter 5 Remote console operation Chapter contents Introduction ................................46 Establishing a Remote Console Session ......................46 How to Connect ............................46 How to Disconnect ...........................47 Differences in Local and Remote Control Session Behavior ..............48...
  • Page 46: Introduction

    Model 3088A Series User Manual 5 • Remote console operation Introduction The PC user (near-end) may configure and verify status of the remote 3088A (far-end) via a Remote Console session. The PC user must log onto the 3088A (near-end) unit to establish a remote console session. Once done, the remote 3088A (far-end) appears as a unit which is locally connected through the console port.
  • Page 47: How To Disconnect

    Model 3088A Series User Manual 5 • Remote console operation Note The local or remote 3088A may be CO or CPE, as long as there is one of each. Either the CO or CPE unit may accept a remote console connection.
  • Page 48: Differences In Local And Remote Control Session Behavior

    Model 3088A Series User Manual 5 • Remote console operation The response upon logging out of the remote console session with the command logout is Console: Remote con- sole connection lost. The following is what is displayed upon a user’s logging out of a remote console session after logging in.
  • Page 49: Software Upgrade

    Chapter 6 Software Upgrade Chapter contents Introduction ................................50...
  • Page 50: Introduction

    Model 3088A Series User Manual 6 • Software Upgrade Introduction The software upgrade feature is available through BOOTP/TFTP. The software upgrade takes approximately 2-3 minutes to complete. To upgrade the software: 1. Connect to the Model 3088A via the Ethernet management port and a Telnet session.
  • Page 51: Reset Configuration To Factory Defaults

    Chapter 7 Reset configuration to factory defaults Chapter contents Introduction ................................52...
  • Page 52: Introduction

    Model 3088A Series User Manual 7 • Reset configuration to factory defaults Introduction The configuration can be reset to factory defaults using DIP switch S1. A factory reset allows a user to recover from a forgotten password. To reset to the configuration: 1.
  • Page 53: Contacting Patton For Assistance

    Chapter 8 Contacting Patton for assistance Chapter contents Introduction ................................54 Contact information..............................54 Patton support headquarters in the USA ......................54 Alternate Patton support for Europe, Middle East, and Africa (EMEA) ............54 Warranty Service and Returned Merchandise Authorizations (RMAs)..............54 Warranty coverage ............................54 Out-of-warranty service ..........................55 Returns for credit...
  • Page 54: Introduction

    Model 3088A Series User Manual 8 • Contacting Patton for assistance Introduction This chapter contains the following information: • “Contact information”—describes how to contact Patton technical support for assistance. • “Warranty Service and Returned Merchandise Authorizations (RMAs)”—contains information about the warranty and obtaining a return merchandise authorization (RMA).
  • Page 55: Out-Of-Warranty Service

    Model 3088A Series User Manual 8 • Contacting Patton for assistance Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro- phes may require replacement.
  • Page 56 Appendix A Compliance information Chapter contents Compliance ................................57 ................................57 Safety ................................57 Radio and TV Interference (FCC Part 15) ......................57 CE Declaration of Conformity ..........................57 Authorized European Representative ........................57...
  • Page 57: A Compliance Information

    Model 3088A Series User Manual A • Compliance information Compliance • FCC Part 15, Class A • EN55022, Class A • EN55024 Safety • UL 60950-1/CSA C22.2 N0. 60950-1 • IEC/EN60950-1 2nd edition • AS/NZS 60950-1 Radio and TV Interference (FCC Part 15) This device generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufacturer’s instructions-may cause interference to radio and television reception.
  • Page 58 Appendix B Specifications Chapter contents Clocking modes..............................59 DTE rate ................................59 Serial interface ...............................59 Serial connector ..............................59 Diagnostics................................59 Status LEDs................................59 Power (Green) ............................59 DSL (Green) .............................59 Link (Green) (E1 only) ..........................59 Terminal (Green) ............................60 TM/ER (Yellow) ............................60 LOS (Red) [Model /K] ..........................60 Link (Green) .............................60...
  • Page 59: B Specifications

    Model 3088A Series User Manual B • Specifications Clocking modes Internal, external, or receive recovered DTE rate All 64k steps from 64 to 5696 kbps Serial interface RS-232 (Model 3088A/A), DCE/DTE selectable V.35 (Model 3088A/CA), DCE/DTE selectable X.21 (Model 3088A/D), DCE/DTE selectable E1 (Model 3088A/K) presents G.703/G.704 interface.
  • Page 60: Terminal (Green)

    Model 3088A Series User Manual B • Specifications Terminal (Green) The Terminal LED glows solid under the following circumstances: • 3088A/CA with V.35 interface and 3088A/A with RS-232 interface: if the serial interface has asserted • 3088A/D with the X.21 interface Configured as DCE: Indicates that the “Control”...
  • Page 61: External Ac Universal Power Supply

    Model 3088A Series User Manual B • Specifications 5 VDC Figure 19. Power connection barrel receptacle 5 VDC diagram External AC universal power supply The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator.
  • Page 62: Line Rates (Dsl Line)

    Model 3088A Series User Manual B • Specifications Line rates (DSL line) All nx64 rates from 192kbps up to 5.696 Mbps Line interface Transformer coupled, 2500 VRMS isolation G.SHDSL physical connection RJ-45, 2-wire polarity insensitive pins 4 and 5 Environment Operating temp: 32–122°F (0–50°C)
  • Page 63: Factory Default Values

    Appendix C Factory default values Chapter contents Factory default values for software-configurable parameters...................64...
  • Page 64: Factory Default Values For Software-Configurable Parameters

    Model 3088A Series User Manual C • Factory default values Factory default values for software-configurable parameters Note The default management IP address is 192.168.200.1. Note The default logout timer value is set for 300 seconds (5 minutes). Table 7. 3088A/CA and 3088A/D...
  • Page 65 Model 3088A Series User Manual C • Factory default values Table 9. 3088A/K Parameter Default value Clock Mode Receive-Recover DSL Timeslots E1 Timeslots E1 Timeslot Map 1-31 E1 Line Type E1 - Fractional E1 Line Code HDB3 E1 Line Build Out...
  • Page 66: Factory Replacement Parts And Accessories

    Appendix D Factory replacement parts and accessories Chapter contents Factory replacement parts and accessories ......................67...
  • Page 67: Factory Replacement Parts And Accessories

    Model 3088A Series User Manual D • Factory replacement parts and accessories Factory replacement parts and accessories Power Supplies PS-03671H1-00 100-240VAC (12V, DC/2A) Wall mount power adapter Power Adapters 12-130 European replacement plug 12-129 American replacement plug 12-131 United Kingdom plug...
  • Page 68: E Interface Pinouts

    Appendix E Interface pinouts Chapter contents Line port ................................69 RS-232 interface..............................69 V.35 interface................................70 E1 interface ................................70 X.21 interface ................................71 Ethernet Console port ............................71...
  • Page 69: Line Port

    Model 3088A Series User Manual E • Interface pinouts Line port RJ-45 connector Pin # Signal No connection No connection No connection Ring No connection No connection No connection RS-232 interface (DTE/DCE orientation) DB-25 female connector Pin # Signal Designation...
  • Page 70: Interface

    Model 3088A Series User Manual E • Interface pinouts V.35 interface (DTE/DCE orientation) DB-25 female connector Pin # Signal Pin # Signal Frame Ground TxC-b (DTE Source) TxD-a (DTE Source) TxD-b (DTE Source) RxD-a (DCE Source) TxC-a (DCE Source) RTS (DTE Source)
  • Page 71: Interface

    Model 3088A Series User Manual E • Interface pinouts X.21 interface D-sub-15 female connector (DTE/DCE orientation) Pin # Signal Frame Ground T - Transmit Data-A (DTE Source) C - Control-A (DTE Source) R - Receive Data-A (DCE Source) I - Indication-A (DCE Source)