    R410A INDOOR UNIT 1. WALL MOUNTED TYPE : ASA07LGC ASA09LGC ASA12LGC ASA14LGC D1D_AS016E/03 2009.03.24...
  • Page 2 FEATURE MODEL „ „ ASA07LGC ASA09LGC ASA12LGC ASA14LGC AO  R07/09/12LG AO  R14LG FEATURES „ „ Energy-Efficiency classification A „ Europe Energy-Efficiency classification A achieved ALL DC „ fan motor i-PAM control (12TYPE, 14TYPE) When operation starts, the machine operates at high voltage and high power and when operation stabilizes, the set temperature is maintained at low voltage.
  • Page 3: Super Quiet

    Super quiet „ Air flow mode can be set in 4 steps and more detailed air flow setting is possible. Fan speed Noise level Quiet dB(A) (07 / 09 / 12 TYPE) Easy maintenance „ Easy maintenance and always clean. Troublesome maintenance has been made easy. Since the front panel is easy to remove, maintenance is also easy.
  • Page 4: Cooling Operation/Dry Operation

    REMOTE CONTROLLER 2-11 WIRED REMOTE CONTROLLER FEATURES „ „ Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) ¾ „ are possible. Four kinds of timers. Easy operation. ¾ „ Built-in timers „ Select from four different timer programs (On/Off/Program/Sleep). Program timer „...
  • Page 5: Signal Transmitter

    FUNCTIONS „ „ START/STOP button MODE button 10°C HEAT button SET TEMP. button ( COIL DRY button Signal Transmitter TIMER MODE button TIMER SET ( ) button FAN CONTROL button ECONOMY button START/STOP button AIRFLOW DIRECTION SET button (Vertical) SWING button RESET button TEST RUN button This button is used when installing the conditioner, and should...
  • Page 6: Specifications

    SPECIFICATIONS WALL MOUNTED Type INVERTER HEAT PUMP Model name AS¾A07LGC AS¾A09LGC AS¾A12LGC AS¾A14LGC Power source 230V~ 50Hz Available voltage range 198-264V ~ 50Hz Cooling European energy label Heating 2.10 2.50 3.40 4.00 Rated BTU/h 7,200 8,500 11,600 13,600 Cooling 0.5 - 3.0 0.5 - 3.2 0.9 - 3.9 0.9 - 5.0...
  • Page 7: Installation Place

    DIMENSIONS MODEL : ASA07LG, ASA09LG, ASA12LG, ASA14LG „ „ (Unit : mm) INSTALLATION PLACE „ „ Wall hook bracket 5 cm or more 6 cm or more 9 cm or more 150 cm or more 180 cm or more (Wall cap) - (01 - 06) -...
  • Page 8: Wiring Diagrams

    WIRING DIAGRAMS MODEL : ASA07LG, ASA09LG, ASA12LG, ASA14LG „ „ TO OUTDOOR UNIT - (01 - 07) -...
  • Page 9: Capacity Table

    CAPACITY TABLE 6-11 COOLING CAPACITY MODEL : ASA07LG „ „ 12.5 Indoor temperature °CDB °CWB °CDB 1.97 1.40 0.33 2.19 1.41 0.34 2.26 1.53 0.34 2.41 1.54 0.34 2.49 1.66 0.34 2.64 1.65 0.35 2.79 1.76 0.35 1.87 1.33 0.37 2.08 1.34 0.38...
  • Page 10: Heating Capacity

    6-21 HEATING CAPACITY MODEL : ASA07LG „ „ 12.5 Indoor temperature °CDB °CDB °CWB 2.25 0.99 2.19 1.01 2.14 1.03 2.09 1.05 2.03 1.07 2.56 1.02 2.50 1.04 2.43 1.06 2.37 1.08 2.31 1.11 2.93 1.05 2.86 1.07 2.79 1.10 2.72 1.12 2.65...
  • Page 11: Air Velocity Distribution

    FAN PERFORMANCE AND CAPACITY 7-1. AIR VELOCITY DISTRIBUTION MODEL : ASA07LG, ASA09LG, ASA12LG „ „ Unit : m/s TOP VIEW Note: FLOW CONTROL PANEL : Horiz. LOUVER : Center Fan speed : High Operation mode : FAN Voltage : 230V Unit : m/s TOP VIEW FLOW CONTROL PANEL : Horiz.
  • Page 12 MODEL : ASA14LG „ „ Unit : m/s TOP VIEW Note: FLOW CONTROL PANEL : Horiz. LOUVER : Center Fan speed : High Operation mode : FAN Voltage : 230V Unit : m/s TOP VIEW FLOW CONTROL PANEL : Horiz. LOUVER : Right &...
  • Page 13 7-21 AIR FLOW MODEL : ASA07LG, ASA09LG, ASA12LG „ „ COOLING „ Number of Fan speed rotations Airflow (r.p.m) HIGH 1440 1200 QUIET zHEATING „ Number of Fan speed rotations Airflow (r.p.m) HIGH 1440 1200 QUIET - (01 - 12) -...
  • Page 14 MODEL : ASA14LG „ „ COOLING „ Number of Fan speed rotations Airflow (r.p.m) HIGH 1500 1300 1020 QUIET zHEATING „ Number of Fan speed rotations Airflow (r.p.m) HIGH 1500 1300 1080 QUIET - (01 - 13) -...
  • Page 15 OPERATION NOISE 8-1. NOISE LEVEL CURVE MODEL : ASA07LG „ „ COOLING HEATING „ „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 High High NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 Quiet NC-15 Quiet 1,000 2,000...
  • Page 16 MODEL : ASA12LG „ „ COOLING HEATING „ „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 High High NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 Quiet NC-20 NC-20 Quiet NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000...
  • Page 17: Sound Level Check Point

    8-2. SOUND LEVEL CHECK POINT - (01 - 16) -...
  • Page 18: Electric Characteristics

    ELECTRIC CHARACTERISTICS Model Name AS Û A07LG AS Û A09LG AS Û A12LG AS Û A14LG Voltage 230 ~ Power Supply Frequency Max Operating Current 10.5 Circuit breaker *1)Wiring Spec. Connection Cable 1.5-2.5 Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 17) -...
  • Page 19: Safety Devices

    SAFETY DEVICES Model Protection form AS Û A07LG AS Û A09LG AS Û A12LG AS Û A14LG Circuit protection Current fuse (PCB) 3.15A 250V Terminal protection Current (thermal) fuse 3A 250V 102°C Thermal protection Fan motor protection MAX. 120±15°C program - (01 - 18) -...
  • Page 20: Optional Parts

    OPTIONAL PARTS Exterior Parts name Model No. Summary Fine dust, invisible mold spores, and harmful microorganisms are absorbed Apple-catechin onto the filter by static UTR-FA16 electricity, and further growth filter is inhibited and deactivated by the polyphenol ingredient extracted from apples. The filter deodorizes by powerfully decomposing absorbed odors using the...
  • Page 21: Wired Remote Controller

    11-11 WIRED REMOTE CONTROLLER FEATURES „ „ Various timer setup (ON / OFF / WEEKLY) are possible. ¾ „ Equipped with weekly timer as standard function. ¾ „ (2 times Start / Stop per day for a week) When setting up a timer, operation mode and a temperature ¾...
  • Page 22: Delete Button

    FUNCTIONS „ „ START/STOP button Pressed to start and stop operation. Set temperature button Selects the setting temperature. Master control button Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY). Fan control button Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH). Economy button Turns the economy efficient mode on and off.
  • Page 23: External Connect Kit

    11-21 EXTERNAL CONNECT KIT This kit allows to operate the air conditioner, such as stopping and starting, using an external device, and output the operation status of the air conditioner. • Only operation and stop signals will be output. Use the remote control to check the operation mode, temperature, and airflow. Check the error information on the display area of the main unit.
  • Page 24 11-2-2. Operating output setting • You can display air conditioner ON / OFF operation by e xternal o utput. Signal specification „ • No voltage contact. • Contact capacity : Max. DC24V 10mA to 1A or less OPERATION Indoor unit status STOP SHORT External output signal...
  • Page 25: Outdoor Unit

    R410A OUTDOOR UNIT 2. SINGLE TYPE : AOR07LGC AOR09LGC AOR12LGC AOR14LGC D1D_AO018E/02 2008.10.03...
  • Page 26 SPECIFICATIONS Type INVERTER HEAT PUMP Model name AOÛR07LGC AOÛR09LGC AOÛR12LGC AOÛR14LGC Power source 230V~ 50Hz Available voltage range 198-264V~ 50Hz Starting current Cooling 1,720 1,720 1,830 2,040 Airflow rate Heating 1,510 1,510 1,600 1,800 Type × Q'ty Propeller fan×1 Motor output Cooling Sound pressure level dB(A)
  • Page 27 DIMENSIONS MODEL : AOR07LG, AOR09LG, AOR12LG „ „ (Unit : mm) Top view Side view Front view Side view MOUNTING POSITION „ „ 100 mm or more 100 mm or more 200 mm or more If the space is larger that is stated, the condition will be the same as that are no obstacles. - (02 - 02) -...
  • Page 28 MODEL : AOR14LG „ „ (Unit : mm) Top view Side view Front view Side view MOUNTING POSITION „ „ 100 mm or more 100 mm or more 300 mm or more If the space is larger that is stated, the condition will be the same as that are no obstacles. - (02 - 03) -...
  • Page 29: Refrigerant Circuit

    REFRIGERANT CIRCUIT MODEL : AOR07LG, AOR09LG, AOR12LG, AOR14LG „ „ Heat exchanger 3-Way ( INDOOR ) valve 2-Way valve Muffler 4-Way valve Strainer Expansion valve Heat exchanger Strainer ( OUTDOOR ) Cooling Heating Refrigerant pipe diameter Liquid : 1/4" (6.35 mm) Gas : 3/8"...
  • Page 30 WIRING DIAGRAMS MODEL : AOR07LG, AOR09LG „ „ TO INDOOR UNIT - (02 - 05) -...
  • Page 31 MODEL : AOR12LG „ „ TO INDOOR UNIT - (02 - 06) -...
  • Page 32 MODEL : AOR14LG „ „ COMPRESSOR REACTOR REACTOR WHITE WHITE WHITE BLACK CONTROLLER PCB ASSY 4-WAY VALVE BLACK THERMISTOR CN30 BLACK BLACK ( PIPE TEMP. ) BLACK CN71 BROWN THERMISTOR BROWN ( DISCHARGE TEMP. ) FAN MOTOR BLACK CN800 BLACK WHITE THERMISTOR YELLOW...
  • Page 33: Capacity Compensation Rate For Pipe Length And Height Diference

    CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFERENCE MODEL : AOR07LG, AOR09LG „ „ Pipe length (m) COOLING 0.872 0.910 Û 1 0.961 0.886 0.925 Indoor unit is upper 0.979 0.965 0.890 0.929 than outdoor unit. 0.992 0.983 0.969 0.893 0.933 Height difference H...
  • Page 34 MODEL : AOR12LG „ „ Pipe length (m) COOLING 0.858 0.868 Û 1 0.929 0.872 0.882 Indoor unit is upper 0.960 0.933 0.876 0.885 than outdoor unit. 0.992 0.964 0.937 0.879 0.889 Height difference H 1.000 0.972 0.944 0.887 0.896 1.000 0.972 0.944...
  • Page 35 MODEL : AOR14LG „ „ Pipe length (m) COOLING 0.893 0.909 Û 1 0.955 0.908 0.924 Indoor unit is upper 0.975 0.959 0.912 0.928 than outdoor unit. 0.992 0.979 0.963 0.916 0.931 Height difference H 1.000 0.987 0.970 0.923 0.939 1.000 0.987 0.970...
  • Page 36: Additional Charge Calculation

    ADDITIONAL CHARGE CALCULATION MODEL : AOR07LG „ „ Refrigerant type R410A Refrigerant amount REFRIGERANT CHARGE „ Pipe length 20g/m Additional charge 0 (Charge less) +100 MODEL : AOR09LG „ „ Refrigerant type R410A Refrigerant amount REFRIGERANT CHARGE „ Pipe length 20g/m Additional charge 0 (Charge less)
  • Page 37: Air Flow

    AIR FLOW MODEL : AOR07LG, AOR09LG „ „ COOLING „ Number of rotations Airflow (r.p.m) 1720 1012 HEATING „ Number of rotations Airflow (r.p.m) 1510 MODEL : AOR12LG „ „ COOLING „ Number of rotations Airflow (r.p.m) 1830 1077 HEATING „...
  • Page 38 MODEL : AOR14LG „ „ COOLING „ Number of rotations Airflow (r.p.m) 2040 1050 1201 HEATING „ Number of rotations Airflow (r.p.m) 1800 1059 - (02 - 13) -...
  • Page 39: Operation Noise

    OPERATION NOISE 8-11 NOISE LEVEL CURVE MODEL : AOR07LG „ „ COOLING HEATING „ „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000...
  • Page 40 MODEL : AOR12LG „ „ COOLING HEATING „ „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency,Hz Octave band center frequency,Hz MODEL : AOR14LG...
  • Page 41 8-21 SOUND LEVEL CHECK POINT - (02 - 16) -...
  • Page 42 ELECTRIC CHARACTERISTICS Model Name AO Û R07LG AO Û R09LG AO Û R12LG AO Û R14LG Voltage 230 ~ Power Supply Frequency Starting Current - (02 - 17) -...
  • Page 43 SAFETY DEVICES Model Protection form AO Û R07LG AO Û R09LG AO Û R12LG AO Û R14LG Current fuse 20A 250V (NEAR THE TERMINAL) Circuit protection Current fuse (MAIN PRINTED 3.15A 250V CIRCUIT BOARD) Fan motor Thermal protection OFF:100 °C OFF:90°C~110°C protection program...

This manual is also suitable for:

As*a09lgc seriesAs*a12lgc seriesAs*a14lgc series

Table of Contents