Fluke 88 V User Manual page 79

Automotive multimeter
Hide thumbs Also See for 88 V:
Table of Contents

Advertisement

Function
mA
60.00 mA
\
400.0 mA
(45 Hz to 2 kHz)
6.000 A
10.00 A
mA
60.00 mA
[
400.0 mA
6.000 A
10.00 A
A B
600.0 A
(45 Hz to 2 kHz)
6000 A
AF
600.0 A
6000 A
1.
AC conversion is ac coupled and calibrated to the rms value of a sine wave input.
W 10 A continuous up to 35 C; < 20 minutes on, 5 minutes off at 35 C to 55 C. 20 A for 30 seconds maximum; > 10 A
2.
unspecified.
3.
Below a reading of 200 counts, add 10 counts.
4.
400 mA continuous; 600 mA for 18 hrs maximum.
Table 15. Current Function Specifications
Range
Resolution
0.01 mA
4
0.1 mA
0.001 A
2
0.01 A
0.01 mA
4
0.1 mA
0.001 A
2
0.01 A
0.1 A
1 A
0.1 A
1 A
Automotive Multimeter
1
Accuracy
Burden Voltage (typical)
3
(1.2 % + 2)
3
(1.2 % + 2)
3
(1.2 % + 2)
3
(1.2 % + 2)
(0.4 % + 4)
(0.4 % + 2)
(0.4 % + 4)
(0.4 % + 2)
3
(1.2 % + 2)
3
(1.2 % + 2)
(0.4 % + 4)
(0.4 % + 2)
Specifications
1.8 mV/mA
1.8 mV/mA
0.03 V/A
0.03 V/A
1.8 mV/mA
1.8 mV/mA
0.03 V/A
0.03 V/A
100 V/ A
100 V/ A
100 V/ A
100 V/ A
69