Appendix; Technical Data - elysia museq Manual

Table of Contents

Advertisement

APPENDIX

Technical Data

Frequency response:
Low Band (Shelf Filter):
Low Band (Cut Filter):
Bottom Band (Peak Filter):
Quality factor (Q):
Middle Band (Peak Filter):
Quality factor (Q):
Top Band (Peak Filter):
Quality factor (Q):
High Band (Shelf Filter):
High Band (Cut Filter):
THD+N @ 0 dBu, 0 Hz -  kHz:
THD+N @ +10 dBu, 0 Hz -  kHz:
Noise floor, 0 Hz - 0 kHz (A-weighted):
Dynamic range, 0 Hz -  kHz:
Maximum input level:
Maximum output level:
Input impedance:
Output impedance:
Input pin assignment:
Output pin assignment:
Power consumption:
Fuse type:
Dimensions (W x H x D):
Weight:
1
<10 Hz - >200 kHz (-0.2 dB)
9 - 200 Hz (+/-15 dB)
9 - 200 Hz
18 - 400 Hz (+/-15 dB)
1.3 (wide) and 0.5 (narrow)
150 Hz - 3.5 kHz (+/-15 dB)
1.3 (wide) and 0.5 (narrow)
700 Hz - 16 kHz (+/-15 dB)
1.3 (wide) and 0.5 (narrow)
1.8 - 35 kHz (+/-15 dB)
1.8 - 35 kHz
0.0037 %
0.0038 %
-91.6 dBu
119 dB
+27 dBu
+27 dBu
10 kOhm
68 Ohm
1. Ground
2. Positive
3. Negative
1. Ground
2. Positive
3. With 68 Ohm to Ground
60 W
230 VAC 0.8 A Slo-Blo
115 VAC 1.6 A Slo-Blo
483 mm x 89 mm x 377 mm
19 " x 3.5" (2 U) x 14.8"
8 kg / 17.5 lb