  • Page 1 R R o o s s e e t t t t a a A A D D 24-bit 2-channel A/D Converter 44.1/48 kHz version & 44.1/48/88.2/96 kHz version Owner’s Manual UV22HR License Agreement ® v3.0 – May 2000 Firmware revision 3.0.0 – inc. Single-Wire...
  • Page 2 Technology within the Rosetta AD may be covered by one or more patents that are the property of Apogee Electronics Corporation. Infringement of said patents may cause a rift in the space-time continuum resulting in your transition to an alternate Universe in which you have given all your money to lawyers.
  • Page 3 Rosetta AD User’s Guide R R o o s s e e t t t t a a A A D D 24-bit 2-channel A/D Converter 44.1/48 kHz version & 44.1/48/88.2/96 kHz version Owner’s Manual UV22HR License Agreement ® v3.0 – May 2000 Firmware revision 3.0.0 –...
  • Page 4: Warnings

    AC voltage ratings for electrical power vary from area to area. Severe damage to your unit is possible if your Rosetta AD is configured incorrectly for your local power. If in doubt, consult an Apogee deal- er. A label adjacent to the power connector indicates the voltage to which the unit was set on leaving the factory.
  • Page 5: Registration & Warranty Information

    Apogee. In the event your Rosetta AD needs to be upgraded or repaired, it is necessary to contact Apogee prior to ship- ping, and a Return Materials Authorization (RMA) number will be assigned. This number will serve as a refer- ence for you and helps facilitate and expedite the return process.
  • Page 6: Declarations Of Conformity

    • 89/336/EEC – EMC Directive Declaration of Conformity – Japan Apogee Electronics Corporation hereby declares that the Rosetta AD, to which this declaration relates, is in material conformity with the VCCI Class A standard. Declaration of Conformity – Australia Apogee Electronics Corporation hereby declares that the Rosetta AD is in material conformity with AN/NZS standard requirements.
  • Page 7: Licensing & Legal Information

    You further acknowledge that title and full ownership rights to the Rosetta AD will remain the exclusive prop- erty of Apogee, and you will not acquire any rights to the UV22HR process except as expressly set forth above. 3. Reverse Engineering You agree that you will not attempt (and, if you are a corporation, you agree to use your best efforts to prevent your employees and contractors from attempting) to reverse compile, modify, translate or disassemble the UV22HR Process Software in whole or in part.
  • Page 8: User's Installation Notes

    Apogee. Remember — before calling technical support at Apogee, you must register this product either by sending in the registration card or by registering on the Apogee Web site (http://www.apogeedigital.com). The techni- cal support specialist will refer to the manual during your call and will expect that you have read it and under- stand the product to some degree.
  • Page 9: Table Of Contents

    Rosetta AD User’s Guide Table of Contents Warnings ...........................4 Registration & Warranty Information ................5 Service Information......................5 Declarations of Conformity....................6 Licensing & Legal Information ..................7 Owner’s record .........................7 User’s Installation Notes ....................8 About This Manual ......................8 The Manual Table of Contents......................9 Quick Start Guide ......................11 The Front Panel.......................12 Power Button...
  • Page 10 Rosetta AD User’s Guide This page intentionally left blank. Page 10...
  • Page 11: Quick Start Guide

    Your Rosetta AD is shipped from Apogee ready to go. It has spent at least two days ‘burning-in’. This burn-in procedure involves powered operation at elevated temperatures to isolate units that would possibly fail due to component defects.
  • Page 12: The Front Panel

    Rosetta AD User’s Guide The Front Panel See also the fold-out front and rear panel diagrams at the end of this manual. POWER BUTTON Press for power on. Press again for power off. SAMPLE RATE Selects the sample rate (sampling frequency) for the digital outputs and word clock output to either 44.1 kHz or 48 kHz (the upper two LEDs are unused).
  • Page 13: Optical Out

    (on analog signals only). Its lack of audible artifacts makes it ideal for use as a final L/R limiter for mixing and mastering. Soft Limit comes calibrated from Apogee to what we feel is an optimum setting based on years of user feedback. The Soft Limit circuit never needs re-calibration;...
  • Page 14: Meter Clear

    Rosetta AD User’s Guide The digital scale (‘dBFS’ or ‘decibel full-scale’) differs significantly from the conventional analog scale. The dif- ference is that these ‘zeros’ are not the same kind of thing. The maximum level on a digital meter is 0dBFS, (a digital “word”...
  • Page 15: The Rear Panel

    NOTE: Be sure to use a quality digital cable for your interconnects. A standard microphone cable is not of high enough bandwidth to carry digital signals reliably. For best sonic results, use a 110 cable created especially for digital audio such as Apogee’s WydeEye AD 110 ohm (part # WE-XX). Page 15...
  • Page 16: S/Pdif

    ‘digital in’. If the receiving device does not automatically switch its sync source to digital in, man- ually select the S/PDIF input as its sync source. For best sonic results, use a 75 coaxial cable created especially for digital audio such as Apogee’s WydeEye AD 75 (part # WE-RR).
  • Page 17: Ac Connector

    ABS 96 tracks and re-assembling them into a stereo 24/96 stream. To do this, you will need an Apogee D/A converter such as that in the Apogee PSX-100. Of course, if you are mastering with the Rosetta 96, you can inform your mastering house that you are using ABS 96 and they can employ their own Apogee unit to recover the stereo data.
  • Page 18: Internal Adjustments

    DO NOT LIFT THE GROUND PIN. When tracing down hums and buzzes, the AC ground pin is often lifted to break ‘ground loops’. Apogee does not recommend that you lift the ground pin on the Rosetta as AC spikes (that have no path to ground) can severely damage the unit.
  • Page 19: About Uv22Hr Super Cd Encoding

    In listening test after listening test, engineers and reviewers alike choose UV22 over all other systems. Many thousands of CD titles have already been mastered using Apogee UV1000 Super CD Encoders, the AD-1000, and the industry-standard AD-8000 and PSX-100. Apogee’s UV22 is today in use in the vast majority of US mastering houses, and it is estimated that as many as 80% of the hit records mastered in the United States today utilize UV22.
  • Page 20: Application Notes

    In addition, some AES/EBU routers may not sup- port ‘double fast’ operation. Apogee supplies both the single-wire and double-wire formats in the Rosetta 96. The formats are selectable via DIP switch #n on the back panel (see page 20).
  • Page 21: Rosetta Ad Specifications

    >> 80 warning. Apogee, UV22, Soft Limit, AMBus, Clocked by Apogee, Input Level, maximum (no gain) Apogee Bit-Splitting and the “96k” device are trademarks or regis- Professional, balanced tered trademarks of Apogee Electronics Corporation. Other trade- marks are the property of their respective owners.
  • Page 22 Rosetta AD User’s Guide The Apogee Rosetta AD – Front & NOTE: These illustrations provide an overview of the controls and Power Switch – Press on, press Output Resolution Selector – Sample Rate Selector – Each time off. There is no power-on LED as...
  • Page 23 Rosetta AD User’s Guide Rear Panels, Controls & Connectors connectors only. Refer to the manual for full operating instructions. Soft Limit – Allows you to get Level Trim – Adjusts the analog LED Bargraph Meters – Indicate maximum level on tape or disc level fed to the A/D converter.