2.8 Ferroli Optimax (optional) Time clock installation.

- Remove outer case by removing four securing screws from the lower sides and lift off.
- Remove two screws securing fascia panel and swing the fascia panel down.
- Remove the four screws securing rear cover of
the fascia and remove.
- Remove clock blanking plate from the panel.
- Mount clock into fascia panel using two screws
provided.
- Take the black cable containing the blue and
brown wires, cut off the molex connector and
strip back the insulation by 4mm, connect the
loose spades to clock terminals 1 & 2.
- Connect stripped end of the blue wire to terminal
N of terminal block.
- Connect the stripped end of the brown wire to
terminal L of terminal block.
- Remove the connector link from the 2 wires
located behind the clock position.
- Connect these to terminal 3 and 5 of the clock.
- Replace fascia and outer case etc, in reverse order.
- Please refer to page 8 for the setting and use of the time clock.
Remove if
external
controls
fitted
230 Vac
22
Existing wiring
Remove if
external
controls
fitted
230 Vac
N
230 V
L
Wiring for integral clock and/or external controls
X3
N
230 V
L
F2A
1 2 3 5
CLOCK
Terminals for inte-
8
gral clock situated
on circuit board
7
compartment
6
5
4
X3
3
2
1
F2A
6
5
4
4
3
10
9
8
7
6
8
7
6
5
3
2
1
2
1
5
4
3
2
1
4
3
2
1
X6
X1
X2
X7
DSP49A1100
CPD5.1
Optimax 25 C
1 2 3 5
CLOCK
1
2
3
4
5
6
X5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents