CMOS Setup Utility - Copyright (C) 1985-2005, American Megatrends, Inc.
SMART Fan Control
Smart Fan Mode
SMART Fan start PWM value
SMART Fan start TEMP.(°C)
DeltaT1
SMART Fan Slope PWM value
CPU FAN Full Limit Temp
: Move
Enter : Select
F1:General Help
Press <Esc> to return to the Smart Fan Function page.
SMART Fan start PWM value (154)
This item is used to set the start PWM value of the smart fan.
SMART Fan start TEMP. (°C) (27)
This item is used to set the start temperature of the smart fan.
DeltaT1 (+3)
This item specifies the range that controls CPU temperature and keeps it from going
so high or so low when smart fan works.
SMART Fan Slope PWM value (3 PWM value/°C)
This item is used to set the Slope Select PWM of the smart fan.
CPU FAN Full Limit Temp (60°C)
This item is used to set the limit temperature of the smart fan.
Press <Esc> to return to the PC Health Status page.
Shutdown Temperature (CPU) (Disabled)
Enable you to set the maximum temperature the CPU can reach before powering
down.
Smart Fan Function
Enabled
Manual
154
Normal: auto ajusts
27
depending on the CPU
+3
temperature.
3 PWM value/°C
60 °C
Quiet: auto minimizes
fan speed for quiet
environment operation.
+/-/: Value
F10: Save
ESC: Exit