Troubleshooting Guide - DeWalt DG series Instruction Manual

Generator/generator with electric start
Table of Contents

Advertisement

Available languages

Available languages

frEE WarnInG laBEl rEplaCEMEnt: If your warning labels become illegible or are missing, call 1-800-4-D
a free replacement.

TrouBLEShooTInG GuIDE

This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or maintenance
personnel can perform some corrective actions, and others may require the assistance of a qualified D
Problem
Engine will not start (See engine instruction manual for more information) .............................................................................................1,2,3,4
No electrical output .................................................................................................................................................................................5,6,7,8,9,18
notE: If there is still no power at the receptacles, take the generator to an authorized D
nearest to you, call 1-800-4-D
Repeated circuit breaker tripping ......................................................................................................................................................................10,11
Generator overheating ......................................................................................................................................................................................10,12
No auto idle ........................................................................................................................................................................................13,14,15,16,17
CoDE
poSSIBlE CauSE
1
Engine switch in OFF position.
2
Choke in wrong position
3
Fuel shut-off valve in closed position
4
Unit loaded during start-up
5
Faulty receptacle
6
Receptacle thermal circuit breaker tripped
WALT (1-800-433-9258)
E
WALT service center. To locate a D
E
poSSIBlE SolutIon
Turn to ON position
Adjust choke accordingly
Open fuel shut-off valve
Remove load from unit
Contact a D
WALT factory service center or a D
e
service center
Depress and reset
27
WALT (1-800-433-9258) for
e
WALT technician or your dealer.
e
WALT service center
E
WALT authorized
e
Code

Hide quick links:

Advertisement

Table of Contents
loading