dbx 576 Owner's Manual page 19

Vacuum tube preamplifier & compressor
Hide thumbs Also See for 576:
Table of Contents

Advertisement

Specifications (cont.)
HIGH Frequency:
MID Frequency:
Gain (all bands):
COMPRESSOR
Threshold Range:
Ratio:
Threshold Characteristic:
Attack/Release Characteristic:
Attack/Release Modes:
Manual Attack Time:
Manual Release Time:
Auto Attack Time:
Auto Release Time:
Output Gain:
LIMITER
Type:
Threshold Range:
Ratio:
Stage 1 Attack and Release Time:
Stage 2 Attack Time
Stage 2 Release Time
SYSTEM PERFORMANCE
DRIVE Control Range:
LEVEL Control Range:
0.5 dB Bandwidth:
Frequency Response:
EIN:
12 kHz, shelving filter
Sweepable from 100 Hz to 8 kHz, bandwidth 1.5
octaves (WIDE) or 0.5 octaves (Narrow)
Sweepable from -15 to +15 dB.
-40 dBu to +20 dBu
1:1 to inf. to 1
¨
Selectable OverEasy
ª
AutoDynamic
Selectable Manual or Auto
Scalable program-dependent. Typically 3 dB/msec to
.04 dB/msec
Scalable program-dependent. Typically 250 dB/sec to 5
dB/sec
Program-dependent. Typically 15ms for 10 dB, 5ms for
20 dB, and 3ms for 30 dB.
Program-dependent. Typically 125 dB/sec rate.
-15 to +15 dB
ª
PeakPlus
Limiter
+4 dBu to > +22 dBu (off)
Infinity : 1
Zero
Program-dependent, typically < 5 msec
Program-dependent, typically 22 dB/sec
+10 dB to +60 dB
-15 dB to +15 dB
15 Hz to > 90 kHz +0/-0.5 dB
<10 Hz to >200 kHz +0/-3.0 dB
Typically -126 dBu, 150
unweighted, 22 kHz measurement bandwidth
or hard knee curves
source impedance,
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents