Amaircare AWW-350 Homeowners Manual & Dealer Installation Instructions

Amaircare AWW-350 Homeowners Manual & Dealer Installation Instructions

Air cleaners/ filters, hepa bypass air filtration system

Advertisement

© 2004 Americair Corporation, Mississauga, Ontario, Canada
HOMEOWNERS MANUAL & DEALER INSTALLATION INSTRUCTIONS

Rules for Safe Installation and Operation

READ AND SAVE
THESE INSTRUCTIONS!
Please read instructions before installing and using the
HEPA Bypass Air Filtration System (HEPA system).
This will help you obtain the full benefit of the HEPA sys-
tem you have selected. It will also help you to avoid
needless service costs.
1. Read this manual carefully. Failure to follow these rules
and instructions could cause a malfunction of the air filter
or unsatisfactory service and could void your warranty.
2. Follow a regular service and maintenance schedule
to ensure efficient operation.
3. For safety and optimized performance of your
HEPA system, all installation and maintenance
must be performed by a professional heating and
ventilation contractor. The installer should be made
aware of your indoor air quality situation and be
familiar with your heating, ventilation and air condi-
tioning equipment.
4. High particulate distribution may occur during initial
start-up of this product after installation or after
scheduled filter changes. Individuals who are high-
ly sensitive to airborne particulates should not be in
the building and allow 24 hours of operation for
removal of particulates from occupied spaces
before re-entry.
WARNING
!
Risk of property damage, injury or death.
Installation, adjustments, alterations, service and main-
tenance must be performed by a qualified technician.
WARNING
!
Risk of Carbon Monoxide Poisoning.
Can cause injury or death.
Do not operate equipment without access panel in
place. Operation of this equipment without all access
panels in place may cause gas fumes from the heat-
ing system to be drawn into occupied spaces.
AIR CLEANERS/
FILTERS
FOR MODELS AWW-350, AWW-675, 8500 & 10000
HEPA BYPASS AIR FILTRATION SYSTEM

Shipping and Packing List

Package 1 of 1 contains:
1 - HEPA System
1 - Complete Filter Set (Packed inside Unit)
1 - Installation Instructions (this manual)
1 - Registration Card
1 - Filter Changes Reminder Label
4 - Self Adhesive Rubber Feet (AWW Models only)
HEPA System Models
Model Airwash Whisper-350 (AWW-350) is
designed to filter air up to a rate of 350 cfm.
Model Airwash Whisper-675 (AWW-675) is
designed to filter air up to a rate of 675 cfm.
Model 8500 is designed to filter air up to a rate of
850 cfm.
Model 10000 is designed to filter air up to a rate of
1000 cfm.
Electrical Shock Hazard.
Can cause injury or death.
Disconnect all electrical power supplies
before servicing.
Do not operate equipment without
access panels in place
AMAIRCARE
WARNING
!

Advertisement

Table of Contents
loading

Summary of Contents for Amaircare AWW-350

  • Page 1: Rules For Safe Installation And Operation

    AIR CLEANERS/ FILTERS AMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM © 2004 Americair Corporation, Mississauga, Ontario, Canada HOMEOWNERS MANUAL & DEALER INSTALLATION INSTRUCTIONS FOR MODELS AWW-350, AWW-675, 8500 & 10000 Rules for Safe Installation and Operation Shipping and Packing List Package 1 of 1 contains:...
  • Page 2: Table Of Contents

    If the air flow through Your Amaircare HEPA system comes with a limited your unit is noticeably reduced, you can inspect the warranty.
  • Page 3: General Information

    General Information Media Filters that is dirty/saturated can be changed. This is more Media filters strain particulates from the air. The filter economical than a system where you need to throw media needs to have tiny holes to allow air to pass out two or three filters when only one needs changing.
  • Page 4: Parts Identification

    Parts Identification AWW-350 & AWW-675 Cabinet Parts Inside Cabinet (Filter Section) Filter Section Access Panel Retaining Clips (2) Intake Collar Motor/Impeller Cabinet Filter Adapter (threaded) Outflow Collar ‘O’ Ring Power Module Model CM71 Motor Section Access Panel Power Cord figure 1. figure 2.
  • Page 5: Parts Identification

    Filter Parts Identification Optional Carbon Canister - HEPA Cartridge Parts - AWW-350 & AWW-675 AWW-350 & AWW-675 For third stage increased removal of chemicals and odors. HEPA Filter Located inside the HEPA Pre-Filter - Foam filter. HEPA Filter Mesh Discard inner carbon filter (Protects HEPA when using the optional Filter)
  • Page 6: Physical Dimensions Of Units

    Physical Dimensions of Unit Model AWW-350 & AWW-675: Filter Section Access Panel Air Intake Air Outflow Motor Section Access Panel figure 9. MODEL NO. Model AWW-350 14.5 27.25 7.875 5.875 1.25 1.25 (368) (692) (200) (149) (406) (32) (32) (76) (216) (51) Model AWW-675...
  • Page 7: Physical Dimensions Of Units

    Physical Dimensions of Unit Models 8500 & 10000: Air Intake Air Outflow Filter Section Access Panel Motor Section Access Panel figure 10. MODEL NO. Models 8500 & 10000 17.25 47.75 50.25 (438) (711) (1213) (254) (254) (1276) (64) (66) (135) Dimensions in inches (mm)
  • Page 8: Dealer Installation Instructions

    Dealer Installation Instructions Forced air handler/furnace systems: The HEPA system should be installed as a bypass system, with part of the return ducted into the HEPA system. The filtered air is then rerouted back into the return air, and continues through the system to be heated/cooled. Typical Return to Return Application Typical Return to Return Application For homes with upflow forced air handler/furnace sys-...
  • Page 9 Dealer Installation Instructions Forced air handler/furnace system with an HRV/ERV This application provides filtration of all Outdoor Air (OA) that is brought into the home through the HRV/ERV, thus reducing the introduction of dust, pollen and mold from the outdoor air. For systems that have HRV/ERV units installed, we recommend ducting the ‘fresh air’...
  • Page 10: Dealer Installation Instructions

    Dealer Installation Instructions Independent Operation: The HEPA systems can be used independently of any other equipment! The intake and outflow of the filtration system can be ducted into the same room to create a cleaner environment almost anywhere. The intake or out- flow can also be ducted elsewhere.
  • Page 11: Operation

    Operation (8500, 10,000 & AWW Units with on/off toggle switch) 1. Make sure that the unit is plugged into a grounded outflow (120 Volt, 60 Hz). 2. For optimum performance, the HEPA system should operate when the indoor air handler/furnace blower is on. 3.
  • Page 12: Maintenance

    Maintenance Proper care and maintenance of your HEPA system Filter Changing Guidelines will ensure years of service. The unit must be turned Pre-Filter: off during service/maintenance or when filters are Dust and other large particles will collect on the pre-fil- being changed.
  • Page 13: Dealer Filter Change Instructions

    Dealer Filter Change Instructions - AWW-350 & AWW-675 carbon filter. WARNING e. Unroll the inner carbon filter and roll it up in the Electrical Shock Hazard. opposite direction (this makes the filter follow a more contoured profile against the inner HEPA fil- Can cause injury or death.
  • Page 14: Dealer Filter Change Instructions

    Dealer Filter Change Instructions - 8500 & 10000 WARNING 3. Inner Carbon Filter Replacement Electrical Shock Hazard. a. Look inside the HEPA cartridge to locate the two ends of the inner carbon filter. Can cause injury or death. b. Pull one end of the old inner carbon filter in and Disconnect all electrical power supplies bend it into a loose roll so it can be removed.
  • Page 15: Dealer Motor Assembly Replacement Instructions

    Dealer Motor Assembly Replacement Instructions 3. Installing the new motor assembly WARNING a. Slide the new motor into the motor mount making Electrical Shock Hazard. sure that the wires go through the smaller hole off- set from the center of the bracket. Can cause injury or death.
  • Page 16: Electrical Diagrams

    Electrical Diagram (AWW-350 & AWW-675) Figure 17. Electrical Diagram (AWW-350 & AWW-675 with on/off toggle switch) Figure 18.
  • Page 17: Electrical Diagrams

    Electrical Diagram (8500 & 10,000) Figure 19.
  • Page 18: Replacement Parts

    99013300 99013300 Use this unit only in the manner intended by the manufacturer. If you have questions, contact Amaircare. Contact your local Amaircare dealer to order replacement parts. For the Amaircare dealer near you, dial 1-800-268-7732 or visit us at www.amaircare.com...

This manual is also suitable for:

Aww-6758500100004000hv6000v2500hv ... Show all

Table of Contents