INSTALLATION OF THE SUPER
STATION
OR A STANDARD WALL PUSH
BUTTON
The Super Station (Deluxe Wall Pushbutton Station) is
a 7 function station designed to work with and
maximize the operation of your opener. Connection
to any other operator may damage the operator and/or
the Super Station. Only connet one Super Station to
the operator. Do not connect more than one Super
Station to the Operator.
If desired, a standard wall push button may be
installed and connected to your opener as an alternate
to the Super Station or in addition to the Super Station.
A standard wall push button is not included in your
hardware package, it can be purchased from your
professional installing dealer or a door bell button
[without light] can be substituted. The operating
parameters for the standard wall push button are
outlined on a page that follows to see if that mode of
operation is right for you. The Super Station is
included with your opener and it's installation is
recommended, the Super Station will provide full
control over the garage door at all times.
YOU MAY CONNECT ONLY ONE SUPER
STATION PER OPERATOR -
ADDITIONAL STANDARD WALL PUSH
BUTTONS MAY BE CONNECTED TO THE
OPERATOR
STEP 1:
After determining a suitable location,
usually near the access door and at least 5 feet above
the floor to prevent use by children, use the Super
Station or the standard wall push button as a guide to
mark the mounting holes. Drill holes for drywall
anchors or screws. NOTE: Do not mount directly to
masonry walls. Use backer board.
of 2-conductor, #22 gauge wire (or heavier) is
required to connect either control to the garage door
operator. Strip approximately 2" of the wire jacket
from one end and 1/2" of insulation from each wire.
Carefully connect one wire to each of the two
terminals. Carefully tuck the loose wires into the case
PHOTOCELL SERIES CONNECTION (RECEIVER FIRST)
IMPORTANT: DO NOT CONNECT SAFE
FINISH PHOTOSYSTEM AND EDGE SYSTEM
AT THE SAME TIME. THE SYSTEMS MUST
BE USED INDEPENDANT OF EACH OTHER.
CONTACT THE FACTORY FOR EDGE SYSTEM
CONNECTION.
WIRE NUT
CONNECTIONS
4
3
OPERATOR
2
1
0
108387
PUSHBUTTON

CONTROL AND AUXILIARY EQUIPMENT

RECEIVER
TRANSMITTER
TWO WIRE
SAFE FINISH PHOTOSYSTEM
T1
T2
SUPER STATION
(DELUXE PUSHBUTTON)
A CHILD OPERATING THE DOOR
CONTROLS RISKS INJURY — OR
DEATH — TO HIMSELF AND OTHERS.
DO NOT ALLOW CHILDREN TO
OPERATE ANY DOOR CONTROLS.
MOUNT THE PUSHBUTTON AT LEAST
5 FT FROM THE FLOOR, OUT OF
REACH OF CHILDREN.
and mount the unit using appropriate screws.
STEP 3:
Run the wire from the control to the
operator, supporting it at 18" intervals with suitable
staples. Leave a sufficient length to make the
necessary connections to the operator terminal strip.
WARNING: SOME LOCAL BUILDING CODES
DO NOT ALLOW SURFACE WIRING. BE
SAFE AND CHECK WITH YOUR LOCAL
BUILDING INSPECTOR FIRST.
IMPROPER DOOR OPERATION
COULD CAUSE INJURY OR DEATH.
WARNING LABEL MUST BE
MOUNTED ON WALL NEAR THE
PUSHBUTTON. ALL WARNINGS AND
INSTRUCTIONS ON THE LABEL
SHOULD BE STRICTLY ADHERED TO.
STEP 4:
Ensure power is OFF to the opener or
disconnect the power from the opener. Strip
approximately 4" of jacket from the end of the wire
and 1/2" insulation from each wire.
Connect to terminals 0 and 1 as shown in
the illustration at left. Support the wire near
the
operator
with wire
ties.
See Step 5,
next page.
WARNING
WARNING
W A R N I N G
!
Child can be pinned under automatic garage
door. Death or serious injury can result.
• Never let child walk or run under moving door.
• Never let child use door opener controls.
• Always keep moving door in sight.
• If person is pinned, push control button or use
emergency release.
• Test door opener monthly:
Refer to your owner's manual
Place one-inch object (or 2x4 laid flat) on floor.
If door fails to reverse on contact, adjust opener.
If opener still fails to reverse door, repair or replace opener.