LOCALIZED INSTALLATION AND OPERATION
In this configuration the dehumidifier will pull air from an area in the home. The air passes through the dehumidifier, where
moisture is removed, and then is returned to the area. This installation is used when the HVAC unit conditions an area other than
where dehumidification is needed. An unconditioned basement or crawl space application is ideal for this installation.
REQUIRED COMPONENTS
None
FIGURE 6 – DUCTING
SUPPLY
AIRFLOW
TO GRILLE OR
TO OPEN SPACE
6
COOLING COIL
AIR CLEANER
HVAC UNIT
1700
OPTIONAL COMPONENTS
Duct Work
24 VAC Transformer (10 VA minimum) for Ventilation Damper
Thermostat Wire
6506 Ventilation Damper
8052 Outdoor Temperature Sensor
Grilles
Normally Closed Condensate Overflow Safety Switch
OUTDOOR AIR INTAKE
FROM GRILLE
OR OPEN SPACE
OPTIONAL
OPTIONAL N.C.
VENT CONTROL
DAMPER
(SEE PAGES 10-11)
RETURN
AIRFLOW
90-946