Air King 6000 Troubleshooting Manual page 4

Flow-through furnace humidifier
Table of Contents

Advertisement

WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE
4
14. Reinstall the solenoid valve onto the humidifier side, feed the
flexible black water supply tube back through the humidifier
side, reinstall the humidifier side (if removed) onto the
humidifier body and secure in place, reconnect the water
supply to the solenoid valve, replace the humidifier's front
cover and secure in place, turn back on the water supply, turn
back on the furnace, and turn on the humidifier
15. Test your repair for leaks and repair if necessary.
Component
Item Description
Humidifier Body
Humidifier Side Panel
Front Cover
Distribution Tray
Filter Holder
Solenoid Valve
Orifice Fitting
Inlet Water Filter
Evaporator Pad
Bypass tube
Water Supply Tube
Water Drainage Tube
Needle Valve Assembly
24 Volt Transformer
Flexible Water Tube
Drain Insert
Mechanical Humidistat
Digital Humidistat
Parts List/
Humidifier Model
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000/6000
5000
6000
A
Component
Warranty
Number
Period
2
Lifetime
17
Lifetime
16
Lifetime
11
1 Year
9
1 Year
20
1 Year
21
N/A
23
N/A
10
N/A
8
1 Year
27
1 Year
4
1 Year
15
1 Year
13
1 Year
14
1 Year
3
1 Year
1 year
mechanism,
1
lifetime on
housing.
1 year
mechanism,
1
lifetime on
housing.
B
Recommended
Maintenance
Inspect yearly, clean with damp cloth.
Inspect yearly, clean with damp cloth.
Inspect yearly, clean with damp cloth.
Inspect when replacing evaporator pad,
clean in warm water and mild soap.
Replace if necessary.
Inspect when replacing evaporator pad,
clean in warm water and mild soap.
Replace if necessary.
Replace as required When replacing
replace the orifice fitting (item 21) and inlet
water filter (item 23) as well.
Replace if plugged, dependant on water
condition. When replacing change the inlet
water filter (item 23) as well.
Replace as required, dependant on water
condition. Good idea to replace with the
evaporator pad (item 10)
Inspect regularly, replace at least yearly,
dependant on water condition.
Inspect regularly; replace if necessary.
Inspect regularly; replace if necessary.
Inspect regularly; replace if necessary.
Inspect regularly; replace if necessary.
Inspect regularly; replace if necessary.
Inspect regularly; replace if necessary.
Inspect when replacing evaporator pad,
clean in warm water and mild soap.
Replace if necessary.
Inspect regularly, Clean housing with damp
cloth – Replace mechanism as required
Inspect regularly, Clean housing with damp
cloth – Replace humidistat electronics as
required
Figure 4.
C

Advertisement

Table of Contents
loading

This manual is also suitable for:

5000

Table of Contents