Technical Specifications - Ei Electronics RadioLINK Ei262 User Instructions

Radiolink mains powered carbon monoxide alarm with rechargeable lithium cell back-up
Hide thumbs Also See for RadioLINK Ei262:
Table of Contents

Advertisement

B16587-R0-262-UC-ENG
15/4/09
3:38 PM
Operating Voltage
Power
Power on Indicator
Sensor
CO Sensitivity
Apparatus Type
Electrical Safety
Electromagnetic
Compatibility
Test/Hush Button
Testing with CO
Page 31

12. TECHNICAL SPECIFICATIONS

: 230±10% VAC, 50Hz
: 1 Watt (90 mA)
: Green Light
: Electrochemical Sensor
: Meets BS EN 50291: 2001.
Unit operates as per Table B.
: Apparatus Type A
: Complies with relevant sections of EN 60335-1: 1994
: Complies with BS EN 50270 including requirements of the R&TTE Directive
Compatibility 1999/5/EC (RF Performance to EN300220-3, EMC to
EN50270) - independently tested
: Checks electronics and horn.
When the unit is alarming, after sensing CO, pressing the Test/Hush button will immediately stop
the horn (the red alarm light will continue to flash). If CO is still present the red alarm light and the
horn will turn on again after about 4 minutes. The unit can only be silenced once during a CO
incident. At 300 ppm CO the unit cannot be silenced. (With interconnected units, the Hush only
works on the alarm sensing CO).
: The red alarm led flashes as soon as the unit detects CO, so there is no
need to retain CO in the unit for several minutes until it alarms.
31