List Of Service Alarms; Alarm Management; Resetting The Haccp Alarm; Troubleshooting Guide - Electrolux SMART 726685 Installation And Operating Instructions Manual

Refrigerated and freezer counters with electronic control
Hide thumbs Also See for SMART 726685:
Table of Contents

Advertisement

C.1.7.4 LIST OF SERVICE ALARMS
· Type "b" service alarms
b1
b2
Reset the HACCP memory
b3
Condenser fan broken
b4
Plug not correctly inserted
· Type "E" service alarms
E1
Sensor short circuit
Sensor broken or disconnected
E2
Sensor short circuit
E3
Sensor broken or disconnected
E4
Sensor short circuit
E5
Sensor broken or disconnected
E6
Sensor short circuit
E7
Sensor broken or disconnected
E8
Low compartment temperature
E9
Low evaporator temperature
E10
C.1.7.5 ALARM MANAGEMENT
· Whenever a high temperature alarm occurs, the display shows
the message "TEMP" and the buzzer is activated.
· To reset the buzzer, hold down the button
HACCP
for 1 second.
· Whenever a type "b" service alarm occurs the display shows
the alarm message code and the buzzer is activated.
· Whenever a type "E" service alarm occurs the display shows
the alarm message code and the buzzer is activated.
CONTACT THE TECHNICAL SERVICE.
· To reset the buzzer, hold down the button
HACCP
for 1 second.
Door open
Microswitch broken
Condenser dirty
No power supply
C.1.7.6 RESETTING THE HACCP ALARM
The system can record up to a max. of 99 compartment high
temperature alarms.
When the memory is full and a "b2" alarm occurs or at the end
of year, the memory must be reset as follows:
HACCP
· Press the button
appears;
· Hold down the buttons
at the same time until "RES" is displayed.
C.1.7.7 TROUBLESHOOTING GUIDE
(problems that can be fixed immediately)
MESSAGE
PROBLEM
The door is open
or
b1
the microswitch
is broken
The
HACCP
b2
memory is
full
The
condenser
b3
temperature
is high
No
b4
current
Refer to the handbook included with the kit for instructions on
installing the accessories.
2 5
until the message "HiSt"
RES
SET
HACCP
ACTION
Check the door.
If closed
contact the
technical service center
Reset
the HACCP memory
Check the condenser,
if clean or uncovered,
contact the
technical service center
Check the feed,
if everything is OK,
contact the
technical service center

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart 726686736684Smart 726682Smart 726683

Table of Contents