Service Alarms - Electrolux SMART 726685 Installation And Operating Instructions Manual

Refrigerated and freezer counters with electronic control
Hide thumbs Also See for SMART 726685:
Table of Contents

Advertisement

buzzer:
buzzer activated
WHAT IS RECORDED?
HACCP
Press
the buzzer goes off; press again for 5
seconds until the alarm (AL1) is displayed.
HACCP
Press again
time are given in a message: "TEMP 78.8F/26C Start 17.05
10-10-99 End——".
b) The alarm has already occurred
77˚/25˚ Temperature ˚F/˚C
68˚/20˚
59˚/15˚
50˚/10˚
41˚/5˚
17:00 18:00
16:00
CHECKING
display:
the message "TEMP" is displayed
buzzer:
buzzer activated
WHAT IS RECORDED?
HACCP
Press
the buzzer goes off; press again for 5
seconds until the alarm (AL1) is displayed.
HACCP
Press again
are given in a message: "TEMP 78.8F/26C Start 17.05 10-10-
99 End——".
To access the recorded HACCP alarms press the
HACCP
button
for 4 seconds; the display will now show
HISt and then AL_1 (alarm symbol); this shows the last alarm
for the max. compartment temperature stored in the PCB. Press
HACCP
the button
for max. compartment temperature. The display now shows:
- TEMP 78.8F/26C (type and value of the alarm for max.
compartment temperature)
- Start date and time (alarm activation date and time)
- End date and time (alarm end date and time)
the temperature, start date and
Critical temperature
Critical temperature
19:00 20:00 21:00 22:00
the temperature, start date and time
to display the value of the last alarm
Press the button
symbol again. Press the button
next alarm for max. compartment temperature. If no button is
pressed within 10 seconds the HACCP section is quitted.
· CHECKING OLD ALARMS
Hold down the button
(last alarm); to select the other alarms (AL2, AL3,...) press
time
· FOR HOW LONG ARE THE ALARMS STORED?
Permanently, at least while there is space in the memory (max.
number of alarms recorded: 99).
C.1.7.3 SERVICE ALARMS
To
access
button
SERVICE ALARM stored in the electronic panel, e.g. "b1" (door
open). Press the button
SERVICE ALARM stored in the electronic panel. If other SERVICE
ALARMS are not stored in the electronic panel, the display shows
"——". If no button is pressed within 5 seconds, the SERVICE
ALARMS section is quitted.
· FOR HOW LONG ARE THE ALARMS STORED?
Until the entire list of stored alarms is displayed. After which
they will remain stored until another alarm occurs: resetting is
automatic.
· ALARM SIGNALING
- alarm button LED flashing
- buzzer activated (acoustic alarm)
· CHECKING ALARMS
Hold down the button
alarm that occurred (a message) and the buzzer is deactivated.
To reset the alarm, press
displayed.
2 4
HACCP
to display the alarm (AL1)
HACCP
HACCP
:: the display shows AL1
.
the
SERVICE
ALARMS
for 4 seconds; the display shows the first
the display shows the last
to display the
press
the
to display the next
until "——" is