HP Model 745 - VME Workstation Installation

Rack mount kit installation note for models 745/132l and 748 industrial systems
Hide thumbs Also See for Model 745 - VME Workstation:

Advertisement

Notices
Information in this Note is subject to change without notice.
Hewlett-Packard makes no warranty of any kind about this manual, including, but not limited to, the implied warranties of mer-
chantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or
direct, indirect, special, incidental or consequential damages about the furnishing, performance, or use of this material.
Warranty
A copy of the specific warranty terms applicable to your Hewlett-Packard product and replacement parts can be obtained from your
local Sales and Service Office.
CopyrightE Hewlett-Packard Company 1993, 1997, 1998
This Note contains information which has been protected by copyright. All rights are reserved. Reproduction, adaptation, or
translation without prior written permission is prohibited, except as allowed under the copyright laws.

Safety Precautions

CAUTION:
S Use of the HP E3664A Rail Kit is required for safe rack mounting.
Multiple units stacked directly on top of each other require only one rail kit on the bottom–most unit.
S If the system will be installed in a closed or multi–unit rack, ensure the ambient temperature does not
exceed 55_ C (131_ F).
S Ensure the airflow is sufficient for safe operation of the system.
S Mount the system in such a way to prevent a hazardous condition due to uneven loading.
S Do not connect the system's power cord to a power extension strip.
Shut down the application and operating system, then turn off the system at both the front panel pushbutton and the power supply
switch. Remove the interface cables and power cord(s) before installing this rack mount kit.
WARNING: Get two people to help you hold the system in position while installing it. A fully configured Model 745 weighs
over 27 Kg (60 pounds); a fully configurted 748 weighs over 31 Kg (68 pounds).
Parts List
745
Item
Qty.
4U Flange
2
4U Spacer
2
7U Flange
7U Spacer
Flange screw
4
Dress screw (with
4
nylon washer)
Dress screw (with
nylon washer)
Clip nut
4
Your installation may require different dress
screws and clip nuts.
Rack Mount Kit Installation Note
For Models 745/132L and 748 Industrial Systems
748
Qty.
Part Number
A2261–00037
A2261–00039
2
A4500–00009
2
A2261–00040
6
0515–1114
0570–1366
4
0570–1597
4
0590–0804
Installation Options
Front
Out
Back
Out
Rack Mount
745 and 748
1
Mast Mount
748 only
Wall Mount
748 only

Advertisement

loading

Summary of Contents for HP Model 745 - VME Workstation

  • Page 1: Safety Precautions

    Information in this Note is subject to change without notice. Hewlett-Packard makes no warranty of any kind about this manual, including, but not limited to, the implied warranties of mer- chantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or direct, indirect, special, incidental or consequential damages about the furnishing, performance, or use of this material.
  • Page 2: Rack Installation

    Mast Installation Model 748 ONLY Figure 1. Middle holes on 1. Attach the side. flange and Rack Installation spacer with flange screws. Figure 2 for Model 748 Front Out. Figure 3 for Model 745 Front or Back Out, CAUTION: Model 748 Back Out. Spacer must be outside of flange You may want to remove the feet.
  • Page 3 Wall Installation 1. Set the workstation upside down, then pry the three front cover bottom Model 748 ONLY. catches loose. Figures 4, 5, and 6. You may want to remove the feet. 465.5 mm 2. Pry side catches loose 235.0 mm EIA Standard Wall Mount for Model 748.
  • Page 4 Part Number: A2677–90011 Printed in U.S.A. Edition E0698 *A2677-90011*...

This manual is also suitable for:

Model 748 - vme workstationE3664a