Configuring the Brocade 5000

SETTING THE SWITCH DATE AND TIME

The date and time switch settings are used for logging events. Switch operation does not depend
on the date and time; a switch with an incorrect date and time value still functions properly.
You can synchronize the local time of the principal or primary fabric configuration server (FCS)
switch to that of an external Network Time Protocol (NTP) server.
To set the date and time of a switch:
1. Log in to the switch as admin.
2. Type the date command at the command line using the following syntax:
Year values greater than 69 are interpreted as 1970-1999; year values less than 70 are
interpreted as 2000-2069. The date function does not support Daylight Savings Time or time
zones, so changes will have to be reset manually.
Example
switch:admin> date
Fri May
switch:admin>
switch:admin> date "0624165203"
Tue Jun 24 16:52:30 UTC 2003
switch:admin>

SYNCHRONIZING LOCAL TIME WITH AN EXTERNAL SOURCE

Use this procedure to synchronize the local time of the principal or primary FCS switch with that of
an external NTP server:
1. Log in as admin.
2. Enter the tsClockServer [ipaddr] command
12
You should back up the configuration on a regular basis to ensure that a complete
configuration is available for downloading to a replacement switch. For specific instructions
about how to back up the configuration, refer to the Fabric OS Administrator's Guide. The
switchShow, fabricShow, and configUpload commands are described in detail in the Fabric OS
Command Reference.
date "MMDDhhmm[CC]YY"
The values represent the following:
MM is the month (01-12).
DD is the date (01-31).
hh is the hour (00-23).
mm is minutes (00-59).
CC is the century (19-20).
YY is the year (00-99).
5 21:50:00 UTC 1989
The ipaddr variable represents the IP address of the NTP server that the switch can access.
This argument is optional; by default, its value is "LOCL".